摘要
介绍由于各互感器校验仪厂家通讯协议不一致,造成其自动检定困难的情况。本文对比了国内主流互感器校验仪通信规约差异和优缺点,根据各自协议优缺点制定了互感器校验仪标准通信协议,可用于互感器校验仪整检装置对互感器校验仪的自动检定。
Transformer calibration instrument belong to important standard transformer test equipments, the automatic verification of transformer calibrator have difficulties because of inconsistent communication agreement. This paper compares the differences, advantages and disadvantages of the domestic mainstream transformer calibrator protocols, and sets up the standard communication protocol of the transformer calibrator according to the advantages and disadvantages of the respective protocols. It can be used in the automatic verification of transformer calibrator used with transformer calibrator verification device.
作者
翟少磊
顾红波
林聪
朱全聪
朱梦梦
Zhai Shaolei;Gu Hongbo;Lin Cong;Zhu Quancong;Zhu Mengmeng(Electric Power Research Institute,Yunnan Power Grid Limited Liability Corporation,Kunming 650217,China;Nanjing Dandick Electric Instrument Company Limited,Nanjing 210049,China)
出处
《云南电力技术》
2018年第3期65-68,共4页
Yunnan Electric Power
关键词
互感器校验仪
自动化检定
标准通信协议
transformer calibrator
automated verification
standard communication protocol