期刊文献+

CT系统参数标定及成像

CT System Parameters Calibration and Imaging
下载PDF
导出
摘要 本文针对CT系统参数标定和图像重建等问题,利用椭圆方程及弦长公式等建立了根据标定模板计算接受信息的公式.并以接收信息的误差平方和为目标函数,结合相关参数的约束条件,建立了非线性最优化模型,利用迭代搜索的方法结合MATLAB优化工具箱完成了CT系统参数标定.通过代数重建算法(ART)以及具有一定去噪能力的全变差极小化算法(TV)等完成了图像重建,并且对标定模板参数的精度和稳定性进行了分析,最后在重建模型和相关结果基础上建立了新的标定模板.结果表明,新模板能改善标定精度和稳定性. In this paper,for the calibration of CT system parameters and image reconstruction,the equations for calculating the acceptance information based on the calibration template were established by using elliptic equations and chord length formulas. Taking into consideration the sum of the error squares of the received information as the objective function and the constraints of the relevant parameters,a non-linear optimization model was established,and the parameters of the CT system were calibrated using the iterative search method combined with the MATLAB optimization toolbox. The algebraic reconstruction algorithm( ART) and the total variation minimization algorithm( TV) with certain denoising capability were used to accomplish image reconstruction,and the accuracy and stability of the calibration template parameters are analyzed. Finally,a new calibration template was achieved on the basis of the reconstruction model and the relative results. The results showed that the new template could improve the calibration accuracy and stability.
作者 周彬 许珊珊 谭兵 ZOU Bin;XU Shan-shan;TAN Bing(College of Science,Southwest Petroleum University,Chengdu 610500,China)
出处 《洛阳师范学院学报》 2018年第5期7-14,18,共9页 Journal of Luoyang Normal University
基金 西南石油大学第17期课外开放实验项目(KSP17237)
关键词 CT成像 平行束 图像重建 代数重建算法 全变差最小化 CT imaging parallel beam image reconstruction algebraic reconstruction algorithm total variation minimization
  • 相关文献

参考文献6

二级参考文献45

  • 1狄红卫,刘显峰.基于结构相似度的图像融合质量评价[J].光子学报,2006,35(5):766-771. 被引量:65
  • 2孙丽娜,原培新.X射线安检设备中探测技术研究[J].中国测试技术,2006,32(3):20-22. 被引量:16
  • 3沈焕锋,李平湘,张良培.一种自适应正则MAP超分辨率重建方法[J].武汉大学学报(信息科学版),2006,31(11):949-952. 被引量:21
  • 4邹晓兵 曾理.锥柬螺旋CT半覆盖扫描重建.光学精密工程,2010,:434-442. 被引量:1
  • 5ALVAREZ R E,MACOVSKI A. Energy-selective reconstruction in X- ray computed tomography [ J ]. Physics in Medicine & Biology, 1976,21 (5) :733-744. 被引量:1
  • 6ZHANG Guo-wei, CHENG Jian-ping,ZHANG Li,et al. A practical re- construction method for dual energy computed tomography [ J]. dour- nal of X-ray Science and Technology, 2008,16(2) :67-88. 被引量:1
  • 7YING Z R, NAIDU R, CRAWFORD C R. Dual energy computed tomography for explosive detection [ J ]. Journal of X-ray Science and Technology,2006,14(4) :67-88. 被引量:1
  • 8XUE Hui,ZHANG Li, CHEN Zhi-qiang. Metal artifact reduction by si- nogram TV inpainting in dual energy computed tomography [ C ]// Proc of the 10th International Meeting on Fully Three-Dimensional [mage Reconstruction in Radiology and Nuclear Medicine. 2009:276- 279. 被引量:1
  • 9LIU Yuan-yuan,CHEN Zhi-qiang, ZHANG Li, et al. Dual energy CT reconstruction method with reduced data[ C]//Proc of the 10th Inter- national Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine. 2009:280-283. 被引量:1
  • 10SZCZYKUTOWICZ T P, CHEN S H. Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing [ J ]. Physics in Medicine & Biology ,2010,55 (21) :6411- 6455. 被引量:1

共引文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部