摘要
在石灰石-石膏湿法脱硫系统运行中最常见的浆液异常情况有浆液"中毒"、浆液反应闭塞和石膏脱水困难。论文从杂质离子的引入和运行参数的调整两个方面分析了浆液异常的原因,并总结我厂运行状况给出浆液异常的处理建议。
In the operation of limestone-gypsum wet desulphurization system, the most common abnormal conditions of slurry are slurry"poisoning", slurry reaction block and gypsum dehydration difficulty. The paper analyzes the causes of abnormal slurry from two aspects: the introduction of impurity ions and the adjustment of operation parameters. It also summarizes the operation situation of our factory, and gives some suggestions to deal with the abnormal slurry.
作者
刘以清
LIU Yi-qing(Guangzhou Power Plant Co.Ltd.,Guangzhou 510160,China)
出处
《中小企业管理与科技》
2018年第17期191-192,共2页
Management & Technology of SME
关键词
燃煤电厂
石灰石
脱硫系统
处理
coal-firedpower plant
limestone
desulfurization system
treatment