期刊文献+

灭火器配置计算方法在转油站的应用 被引量:1

Application of Fire Extinguisher Configuration Calculation Method in Oil Transfer Station
下载PDF
导出
摘要 转油站作为油气集输的节点,在油田生产中具有相当重要的作用。在转油站合理地配备灭火器对预防火灾事故具有重要意义。依据Q/SY 129—2011《输油气站消防设施设置及灭火器材配备管理规范》和GB 50140—2005《建筑灭火器配置设计规范》两项标准,并结合现场火灾种类和火灾危险等级确定灭火器设置点数和每个点数灭火器的数量。 As a node of oil and gas gathering and transportation, the oil transfer station plays an important role in oilfield production. The reasonable installation of fire extinguisher is of great significance to prevent fire accidents. According to Q/SY 129-2011 "fire station installation and fire extinguishing equipment management specification" and GB 50140-2005 "building fire extinguisher configuration design code" two standards, and com-bined with the field fire types and fire hazard grades to determine the number of fire extinguishers and the num-ber of every point.
作者 鲁建舒
出处 《石油石化节能》 2018年第6期54-56,共3页 Energy Conservation in Petroleum & PetroChemical Industry
关键词 灭火器 转油站 计算方法 火灾危险等级 fire extinguisher oil transfer station calculation method fire danger grade
  • 相关文献

参考文献2

  • 1穆剑主编..油气田生产岗位危害识别与评价手册[M].北京:石油工业出版社,2012:163.
  • 2吴九辅编著..安全防爆[M].北京:石油工业出版社,2012:342.