Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases 被引量:1

Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases
下载PDF
导出
摘要 AIM: To compare the results of 25 MHz and 50 MHz ultrasound biomicroscopy(UBM) regarding the image characteristics of the lens and its related diseases and to discuss the application value of 25 MHz UBM in ophthalmology. METHODS: A total of 302 patients(455 eyes) were included in this study from November 2014 to May 2015. Patient ages ranged from 5 to 89 y(mean±SD: 61.0±17.7 y). Different cross-sectional images of the lens were collected to compare and analyze the image characteristics and anterior segment parameters using 25 MHz and 50 MHz UBM in axial and longitudinal scanning modes, respectively. SPSS 19.0 for Windows, paired t-tests and B&A plot analysis were used for data analysis, and a value of P〈0.05 was considered statistically significant. RESULTS: The 25 MHz UBM images displayed the lens shape more clearly than 50 MHz UBM images. Particularly for cataracts, the whole opacity of the lens was shown by 25 MHz UBM, but 50 MHz UBM only showed part of the lens. The means of the anterior segment parameters obtained using 25 MHz and 50 MHz UBM were as follows: central corneal thickness: 0.55±0.03 and 0.51±0.04 mm, respectively; central anterior chamber depth: 2.48±0.54 and 2.56±0.56 mm, respectively; and central lens thickness: 4.26±0.62 and 4.15±0.56 mm, respectively. A statistically significant difference was found between the results obtained with 25 MHz UBM and those obtained with 50 MHz UBM. The two devices had a good agreement in measuring the anterior segment parameters. CONCLUSION: The 25 MHz UBM had an obvious advantage in showing the lens shape. It can provide reliable imaging of the lens and its related diseases and has a high application value for ophthalmology. AIM: To compare the results of 25 MHz and 50 MHz ultrasound biomicroscopy(UBM) regarding the image characteristics of the lens and its related diseases and to discuss the application value of 25 MHz UBM in ophthalmology. METHODS: A total of 302 patients(455 eyes) were included in this study from November 2014 to May 2015. Patient ages ranged from 5 to 89 y(mean±SD: 61.0±17.7 y). Different cross-sectional images of the lens were collected to compare and analyze the image characteristics and anterior segment parameters using 25 MHz and 50 MHz UBM in axial and longitudinal scanning modes, respectively. SPSS 19.0 for Windows, paired t-tests and B&A plot analysis were used for data analysis, and a value of P〈0.05 was considered statistically significant. RESULTS: The 25 MHz UBM images displayed the lens shape more clearly than 50 MHz UBM images. Particularly for cataracts, the whole opacity of the lens was shown by 25 MHz UBM, but 50 MHz UBM only showed part of the lens. The means of the anterior segment parameters obtained using 25 MHz and 50 MHz UBM were as follows: central corneal thickness: 0.55±0.03 and 0.51±0.04 mm, respectively; central anterior chamber depth: 2.48±0.54 and 2.56±0.56 mm, respectively; and central lens thickness: 4.26±0.62 and 4.15±0.56 mm, respectively. A statistically significant difference was found between the results obtained with 25 MHz UBM and those obtained with 50 MHz UBM. The two devices had a good agreement in measuring the anterior segment parameters. CONCLUSION: The 25 MHz UBM had an obvious advantage in showing the lens shape. It can provide reliable imaging of the lens and its related diseases and has a high application value for ophthalmology.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1152-1157,共6页 国际眼科杂志(英文版)
关键词 25 MHz ultrasound biomicroscopy 50 MHz ultrasound biomicroscopy lens diseases 25 MHz ultrasound biomicroscopy 50 MHz ultrasound biomicroscopy lens diseases
  • 相关文献

参考文献1

二级参考文献7

  • 1Wang M. Corneal topography in the wavefront era. A guide for clinical application. Thorofare: SLACK, Inc. 2008:13. 被引量:1
  • 2Javaloy J, Vidal MT, Villada JR,et al. Comparison of four corneal pachymetry techniques in corneal refractive surgery. J Refract Surg 2004; 20(1):29-34. 被引量:1
  • 3Barkana Y, Gerber Y, Elbaz U, et al. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg 2005; 31(9):1729-1735. 被引量:1
  • 4Zhao J, Chen Z, Zhou Z,et al. Evaluation of the repeatability of the Lenstar and comparison with two other non-contact biometric devices in myopes. J Clin Exp Optom 2013; 96(1):92-99. 被引量:1
  • 5Ho T, Cheng AC, Rao SK,et al. Central corneal thickness measurements using Orbscan II, Visante, ultrasound and Pentacam pachymetry after laser in situ keratomileusis for myopia. J Cataract Refract Surg 2007; 33(7):1177-1182. 被引量:1
  • 6Aristodemou P, Cartwright NE, Sparrow JM, et al. Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg 2011; 37(1):63-71. 被引量:1
  • 7孙成淑,黄永志,张小兰,王琳.Lenstar LS900与SIRIUS眼前节分析系统对角膜中央厚度测量结果的比较[J].国际眼科杂志,2012,12(9):1711-1712. 被引量:5

共引文献3

同被引文献7

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部