期刊文献+

600MW机组引风机叶片损坏原因分析以及改进措施 被引量:4

Reasons for Induced-draft Fan Blade Damage in 600 MW Unit and Improvement Measures
下载PDF
导出
摘要 通过对山西兆光600 MW机组3#锅炉静叶可调轴流引风机叶片断裂事故进行分析,总结了风机失速的主要原因,并从烟道阻力、引风机风量、机组负荷波动这3方面提出改进措施,经过长期调试后,提高了引风机的安全性和稳定性,改善了风机失速问题。 The main reasons for the fan stall were summarized through the analysis of the blade fracture accident in the static blade adjustable axial flowfan of the No. 3 boiler of the 600 MW in Shanxi Zhaoguang Power Generating Company. The corresponding improvement measures were put forward according to the resistance in the chimney flue,the air volume of the induced draft fan,and the load fluctuation. It is verified that these measures could improve the security and stability of the induced-draft fan and resolve the fan stall after operating for a long time,.
作者 周朋 刘伟 ZHOU Peng;LIU Wei(Shanxi Zhaoguang Power Generating Company Lid,,Huozhou 031400,Shanxi Province)
出处 《沈阳工程学院学报(自然科学版)》 2018年第3期223-231,共9页 Journal of Shenyang Institute of Engineering:Natural Science
关键词 600MW机组 引风机 变频器 叶轮断裂 失速 600 MW Unit Induced-draft fan Frequency converter Impeller fracture Stall