Characterization and comprehension of corona partial discharge in air under power frequency to very low frequency voltage
下载PDF
导出
摘要 For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies. For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第5期117-125,共9页 等离子体科学和技术(英文版)
基金 supported by the National Key R&D Program of China(2017YFB0902704) the Science and Technology Project of SGCC(GY71-15-048)
关键词 CORONA partial discharge low frequency voltage impulse current method statisticalparameters corona partial discharge low frequency voltage impulse current method statisticalparameters
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部