摘要
针对某电厂上汽机组调门异常关闭事件,全面分析调门伺服阀异常症状,深入剖析事故原因,并提出整改和防范措施。
Taking the abnormal closing event of the regulating valve of the steam supply unit,the abnormal symptoms and the cause of the accident were analyzedin depth.The rectification and preventive measures were proposed.
作者
王栋
WANG Dong(Guangdong Huizhou PinghaiPower Generation Co.Ltd.,Huizhou 516300,China)
出处
《电工技术》
2018年第14期22-23,共2页
Electric Engineering
关键词
调门异常
伺服阀
防范措施
abnormal regulating valve
servo valve
preventive measures