埋地管道阴极保护数学模型中管道防腐层绝缘电阻的物理意义 被引量:1

The Physical Meaning of Insulating Resistance on Pipeline Corrosion Layer in the Mathematical Model of Buried Pipeline Cathodic Protection
下载PDF
导出
摘要 本文重述了埋地管道阴极保护的传输理论及建立的数学模型并系统阐述了各项参数的物理概念。主要参数有:沿管道纵向各点的电流、电位分布规律及相关的各项参数:管道任意点的对地电位(V);管道任意微段的纵向电流(mA);金属管的电阻率(Ω?mm2/m);金属管的纵向电阻(Ω/m);埋地管道与大地之间散流电阻(Ω?m)(又称过渡电阻、接触电阻);管道防腐层绝缘电阻(Ω?m2)(又称管道覆盖层绝缘电阻、防腐层绝缘面电阻、防腐层绝缘电阻率);衰减系数(1/m)(又称传播常数)及各项参数之间的关系。 This paper mainly describes the transmission theory and the mathematical model of buried pipeline cathode protection,including the concept of the physical parameters.The main parameters are:current and potential distribution and related parameters of the pipeline's longitudinal points:pipeline-soil potential(V);longitudinal current of the pipeline's arbitrary micro-channels(mA);resistance Rate of metal pipe(Ωmm2/m);longitudinal resistance of metal pipe(Ω/m);the resistance of stray current between buried pipeline and the earth(Ωm)(also known as:transitional resistance,contact resistance);pipeline coating insulation resistance(Ωm2)(also known as:Pipeline cover insulation resistance,insulation resistance of anti-corrosion layer,insulation resistance rate of anti-corrosion layer);attenuation coefficient(1/m)(also known as:diffuse constant) and relations between the various parameters.
出处 《科技传播》 2010年第6期133-135,共3页 Public Communication of Science & Technology
关键词 埋地管道 阴极保护 汇流点 传输参数 管道防腐层绝缘电阻 Buried pipeline Cathode protection Convergence point Transmission parameters Pipeline coating insulation resistance
  • 相关文献

参考文献1

  • 1[德]贝克曼(Baeckmann,W·V·) 著,赖敬文.阴极保护简明手册[M]石油工业出版社,1987. 被引量:1

同被引文献4

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部