摘要
针对240 t/h循环流化床锅炉同一根后包墙管接近位置连续出现2次泄漏,分析泄漏原因及暴露出的管理问题,采取相应处理措施,保证了该锅炉稳定运行。
Leakage occurred twice on the same tube of rear wall enclosure superheater tube in a 240 t/h circulating fluidized bed boiler. Reasons were analyzed together with exposed management problem.Corresponding measures were taken to guarantee the boiler in stable operation.
作者
殷常亮
王晖
Yin Changliang;Wang Hui(Shaanxi Weihe Coal Chemical Co.,Ltd.,Weinan 714000;Yanchang Petroleum Group Yah'an Refining Factory,Yah'an 727400)
出处
《大氮肥》
CAS
2018年第3期182-184,共3页
Large Scale Nitrogenous Fertilizer Industry
关键词
循环流化床锅炉
后包墙管
泄漏
circulating fluidized bed boiler
rear wall enclosed superheater tube
leakage