地下车库联络道为连接地面道路与地下车库的地下机动车集散道路,服务区域内到达交通,提高区域静态交通出行效率,缓解核心区地面人车矛盾,改善商务区地面环境品质,实现低碳交通理念越来越多地出现在各城市中。地下车库联络道相关的设计标准较少,目前只有参考地下停车库相关规范和道路与公路隧道设计标准进行设计。现通过对地下车库联络道供电系统项目做一个归纳总结,并从变压器的选择,以及照明设计等方面提出思考且加以进行探讨,为以后此类的项目设计提供有益的参考。
The linking taxiway of underground parking is the collector-distributor road of underground motored vehicles linking the ground road and underground parking, and to reach the traffic within the service area. More and more cities are paying attention to the concept of improving the traveling efficiency of regional static traffic, alleviating the contradiction between people and vehicle at the ground of core area, improving the ground environmental quality in the business district, and achieving the low carbon transportation. There are a few design standards related to the linking taxiway of underground parking. At present, there are only the relative standards of underground parking and the design standards of road and highway tunnel for reference during design. The article summarizes a power supply system project of linking taxiway in underground parking, and discusses the selection of transformer and the design of lighting, which can provide the beneficial reference for the design of the similar projects.
出处
《城市道桥与防洪》
2018年第7期365-368,共4页
Urban Roads Bridges & Flood Control
关键词
地下车库联络道
负荷等级
变压器
基本照明
linking taxiway of underground parking
load level
transformer
base lighting