根据全热回收空调系统的特点,分析了各参数对系统的影响。以某综合医院住院部大楼全热回收空调和生活热水系统为研究对象,利用TRNSYS软件建立模型,计算得到了优化的全热回收器出水温度、冷水机组制冷量、蓄热水箱容积。
Based on the characteristics of air-to-air total heat recovery air conditioning system, analyses the influence of each parameter on the system. Taking the air conditioning and domestic hot water system of the inpatient building in a general hospital as the research object, establishes a model with TRNSYS software, and obtains the optimized total heat recovery water outlet temperature, chiller cooling capacity and heat storage tank volume.
作者
邹立成
张晓莉
孙世川
潘茜
Zou Licheng;Zhang Xiaoli;Sun Shichuan;Pan Qian(China Aviation Planning and Design Institute (Group) Co., Ltd., Beijing, Chin)
出处
《暖通空调》
2018年第6期87-90,共4页
Heating Ventilating & Air Conditioning
关键词
全热回收
生活热水
优化方案
出水温度
制冷量
节能
环保
total heat recovery
domestic hot water
optimization scheme
water outlet temperature
cooling capacity
energy saving