摘要
分析地下式污水厂各区域臭气分布及逸散情况,对除臭技术进行比较分析。针对地下污水厂不同区域的臭气情况和工艺要求,选用微生物除臭和离子除臭两种除臭技术,现场感受和实际测量结果表明通风除臭系统效果显著。为地下污水厂的通风除臭设计提供参考。
The situation where distribution and dissipation of odor are in the underground wastewater treatment plant was analyzed, and various deodorization technology were analyzed. Directed against odor conditions and technical requirements for the different regions in the underground wastewater treatment plant, microorganism and ion deodorization technology was selected, and the results of field experience and actual measurement show that the effect of the ventilation deodorization system is remarkable. It provides a reference for the ventilation and deodorization design of the underground wastewater treatment plant.
作者
谢艺强
XIE Yi-qiang(Guangzhou Municipal Engineering Design & Research Institut)
出处
《建筑热能通风空调》
2018年第4期103-105,49,共4页
Building Energy & Environment
关键词
地下式污水厂
臭气分布及逸散
除臭技术
除臭系统
underground wastewater treatment plant
distribution and dissipation of odor
Deodorization technology
Deodorization system