期刊文献+

适用于钠冷快堆检测的超声波导杆仿真研究 被引量:1

Simmulations of Ultrasonic Waveguide Transducer for The Under-sodium Viewing in SFR
下载PDF
导出
摘要 采用有限元仿真的方法,针对适用于钠冷快堆堆内高温环境的超声波导杆的声波传播特性进行了仿真研究,分析了不锈钢超声波导杆中尾随脉冲出现的原因,并针对这一现象,分别对高温下的圆柱形、单锥形、双锥形超声波导杆进行仿真研究,实验结果表明,高温环境有利于波导杆噪声的抑制,单、双锥形超声波导杆对于噪声的抑制具有显著的效果。 Study on the acoustic propagation characteriatics of ultrasonic waveguide transducer which applicable to the high temperature environment in soudium-cooled fast reactor by using finite element simulation. Analyze the reason of the following pulse in stainless steel ultrasonic waveguide transducer. And in response to this phenomenon, we conduct some cimulation studies on cylindrical, single cone and double cone ultrasonic waveguide transducer in high temperature environment respectively. The results show that the high temperature environment helps the suppress noise and the single cone and double cone ultrasonic waveguide transducer have a signicicant effect on suppressing the noise.
作者 袁天戈 杨建伟 刘铱 YUAN Tian-ge;YANG Jian-wei;LIU Yi(China Institute of Atomic Energy,Beijing 102413,China)
出处 《科技视界》 2018年第8期114-117,共4页 Science & Technology Vision
关键词 超声检测 钠冷快堆 钠下成像 波导杆 软件仿真 Ultrasonic testing Sodium-cooled fast reactor Under-sodium viewing Ultrasonic Waveguide Transducer Software simulation
  • 相关文献

参考文献1

二级参考文献3

  • 1[1]Jen C K,Piche L,Bussiere J F.Long isotropic buffer rods[J].Acoustical Society of America,1990,88 (1):23-25. 被引量:1
  • 2[2]Jen C K,Legoux J G,Parent L.Experimental evaluation of clad metallic buffer rods for high temperature ultrasonic measurements[J].NDT & E International,1999,33 (2000):145-153. 被引量:1
  • 3[3]Garcia-Alvarez J,Yanez Y,Prego J L.Noise level analysis in buffer rod geometries for ultrasonic sensors[J].Ultrasonics,2006,44 (2006):1093-1100. 被引量:1

共引文献6

同被引文献3

引证文献1

相关作者