在分析导线和配变损耗特性以及10 kV线路理论线损率影响因素的基础上,结合贵州电网10 kV线路网架结构特点,从线损率大小角度,提出了贵州电网10 kV线路分类方法和标准,将贵州电网所有10 kV线路划分为18种类型,并选取特征参数值对每种类型10 kV线路建立了理论线损率计算模型。利用等值电阻法,计算得到贵州电网18种类型的10 kV线路理论线损率标杆值。该标杆值为贵州电网所有10 kV线路制定线损管理目标和电网规划设计与建设改造线损控制目标提供理论依据和参考值。
The influence factors of wire and distribution transformer loss characteristics and 10 kV line theoretical line loss rate are analyzed in this paper. Based on the structure characteristics of 10 kV line of Guizhou Power Grid,the classification method and standard of Guizhou Power Grid 10 kV line are put forward from the perspective of the size of the line loss rate. All 10 kV lines of Guizhou Power Grid are divided into 18 types,and the theoretical line loss rate calculation model is established for each type of 10 kV line by selecting the characteristic parameter value. Using the equivalent resistance method,the theoretical line loss rate benchmarking value of 18 types 10 kV line of Guizhou Power Grid is calculated. For all 10 kV line of Guizhou Power Grid to develop line loss management objectives and line loss control objectives of power grid planning,design,construction and transformation,the benchmarking value provides the theoretical basis and reference value.
出处
《电力大数据》
2018年第1期57-65,共9页
Power Systems and Big Data
关键词
%10XV线路
线损率
计算模型
标杆值
10 kV line
line loss rate
calculation model
benchmarking value