摘要
为了研究高压静电消电效果和静电防护有效性,采用离子化测试方法,对影响大气压下针状电极电晕放电的电压、频率、消电距离、电极间隙、平衡电压等因素进行了系统测试与分析.结果表明,交流高压电晕放电在频率[1.8kHz,2.0kHz]区间内具有最佳消电效果;直流和脉冲高压电晕消电具有明显逆带电现象,且消电效果随电压升高、消电距离减小而提高.
In order to study the effect of high voltage electrostatic discharge elimination and the effectiveness of electrostatic protection,ionization test method was adopted to measure and analyze the influencing factors of needle electrode corona discharge at atmospheric pressure,such as voltage,frequency,power dissipation distance,electrode gap,balance voltage and so on.The result indicates that,the best power dissipation effect appears in high-voltage corona discharge within the frequency range of 1.8 kHz to 2 kHz;the DC and pulse corona discharge with high voltage has an obvious reverse charging effect,and the elimination effect increases with the increase of the voltage and the decrease of the distance.
作者
王艳平
曾丹
张同来
缪劲松
WANG Yan-ping1,2, ZENG Dan2, ZHANG Tong-lai1 , MIAO Jin-songa(1. State Key Laboratory of Explosion Science and Technology, Beijing Institute of Technology, Beijing 100081, Chiaa~ 2. Safety Technology Research Institute of Ordnance Industry, Beijing 100053, China; 3. Static Research Laboratory of Beijing Institute of Technology, Beijing Institute of Technology, Beijing 100081, Chin)
出处
《北京理工大学学报》
EI
CAS
CSCD
北大核心
2018年第2期190-195,共6页
Transactions of Beijing Institute of Technology
基金
北京理工大学爆炸科学与技术国家重点实验室重点基金项目(ZDKT17-01)
关键词
高压静电消除器
电晕放电
离子风
high-voltage static eliminator
corona discharge
ionic wind