摘要 目的探讨分析术中脊髓神经电生理监测与不同肌松水平的关联性。方法选取进行术中脊髓神经电生理监测的脊柱损伤患者40例,采用咪达唑仑和丙泊酚静脉麻醉,多库氯铵维持肌松,监测肌松水平状况和两种电生理监测方式(体感诱发电位和运动诱发电位)的波幅和潜伏期。结果体感诱发电位监测对于不同肌松水平的波幅和潜伏期差异均无显著性(P>0.05),运动诱发电位监测对于不同肌松水平的潜伏期差异无显著性(P>0.05),但右下肢与左上肢的波幅有显著差异(P<0.05)。结论不同肌松水平对体感诱发电位无显著影响,而对MEP有所影响,主要是影响不同部位的波幅;而运动诱发电位波形的改变也有助于提示患者的脊髓神经缺血或损伤;TOF中的T_1处于45%~55%基础值是较为理想的肌松水平。
出处 《中国临床医生杂志》 2018年第3期330-331,共2页 Chinese Journal For Clinicians
基金 河北省医学适用技术跟踪项目(G2015051)
  • 相关文献

参考文献4

二级参考文献46

  • 1李群喜,乔慧,李建珉,朱军,刘淑玲,王明然,刘莉.七氟醚和异丙酚对上肢体感诱发电位的影响[J].临床神经电生理学杂志,2007,16(4):199-203. 被引量:12
  • 2Sala A, Brieolo A, Faccioli F, et al. Surgery for intramedullary spinal cord tumors:the role of intraoperative(neurophysiological)monitoring [J]. 2007,16(Suppl 2): 130. 被引量:1
  • 3Kothbauer K F, Deletis V, Epstein F J. Motor-evoked potential mon- itoring for intramedullary spinal cord tumor surgery: correlation of clinical and neurophysiological data in a series of 100 consecutive procedures[J]. Neurosurg Focus,1998,4(5):e1. 被引量:1
  • 4Malhotra N R, Shaffrey C I. Intraoperative eleetrophysiologieal moni- toring in spine surgery[J]. Spine (Phila Pa 1976), 2010,35(25):2167. 被引量:1
  • 5Sutter M, Eggspuehler A, Muller A, et al. Multimodal intraoperative monitoring: an overview and proposal of methodology based on 1,017 cases[J]. Eur Spine J, 2007,16(Suppl 2):S153. 被引量:1
  • 6Pajewski T N, Arlet V,Phillips L H .Current approach on spinal cord monitoring:the point of view of the neurologist,the anesthesio- lo-gist and the spine surgeon[J]. Eur Spine J, 2007, 16(Suppl 2): 115. 被引量:1
  • 7Sloan T B, Heyer E J. Anesthesia for intraoperative neurophysiologic monitoring of the spinal cord[J]. J Clinical Neurophysiol, 2~02,19 (5):430. 被引量:1
  • 8Tobias J D, Goble T J, Bates G, et al. Effects of dexmedetomidine on intraoperative motor and somatosensory evoked potential monitoring during spinal surgery in adolescents[J]. Paediatr Anaesth, 2008,18 (11):1082. 被引量:1
  • 9Soghomonyan S, Moran K R, Sandhu G S. Anesthesia and evoked re- sponses in neurosurgery[J]. Front Pharmacol, 2014,5:74. 被引量:1
  • 10Kim W H, Lee J J, Lee S M, et al. Comparison of motor-evoked po- tentials monitoring in response to transcranial electrical stimulation in subjects undergoing neurosurgery with partial vs no neuromuscu- lar block[J]. Br J Anaesth, 2013,110(4):567. 被引量:1

共引文献58

同被引文献5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部