期刊文献+

基于豁免源的核技术实验教学设计 被引量:1

Design on experimental teaching of nuclear technology based on exemption source
下载PDF
导出
摘要 从辐射安全和管理的角度考虑,针对目前核技术实验教学中采用活度较低的豁免源,重新设计了传统核技术实验教学中部分依赖于较强放射源的实验内容,采用基于多道分析器的能谱测量取代了基于定标器的计数测量的实验方案,利用豁免源得到了很好的实验结果,同时使学员对γ射线与物质的相互作用有了更加清楚的认知,表明了该实验方案的可行性。 From the viewpoint of radiation safety and management,the exemption source with lower activity is mostly used for the experimental teaching of the nuclear technology in many colleges and universities.In view of this situation,the experimental content for the teaching of the traditional nuclear technology which is partly dependent on the strong radioactive source is redesigned.The energy spectrum measurement based on the multichannel analyzer is used to replace the counting and measuring experimental scheme based on the scaler,and good experimental results are obtained by using the exemption source.At the same time,the students can get a clearer understanding of the interaction betweenγ-ray and substance,which shows the feasibility of the experimental scheme.
出处 《实验技术与管理》 CAS 北大核心 2018年第2期37-39,49,共4页 Experimental Technology and Management
基金 国家自然科学基金青年项目(11505287)
关键词 核技术 实验教学 豁免源 nuclear technology experimental teaching exemption source
  • 相关文献

参考文献10

二级参考文献66

  • 1牟海维,韩建,李中伟.一种新型的时间-幅度变换器[J].核电子学与探测技术,2004,24(6):612-615. 被引量:3
  • 2谢建军,杨培志,廖晶莹.卤化镧系LnX_3(Ce)闪烁晶体的研究进展[J].无机材料学报,2005,20(3):522-528. 被引量:18
  • 3张晓鹏.美国大学创新人才培养模式探析[J].中国大学教学,2006(3):7-11. 被引量:304
  • 4Van Loef EVD, et aI. High-energy-resolution scintillator: Ce^3+ activated LaCl3 [J]. Appl Phys Lett, 2000, 77(10) :1467. 被引量:1
  • 5Van Loef EVD, et al. scintillation properties of Lacl3 :Ce crystals: fast, efficient, and high-energy resolution scintillators[J]. IEEE Trans Nucl Sci, 2001, NS248 (3): 341. 被引量:1
  • 6Van Loef EVD, et al.High-energy-resolution scintillator: Ce activated LaBr[J]. Appl Phys Lett, 2001, 79(10) : 1573. 被引量:1
  • 7Van Loef EVD, et al. Scintillation properties ol LaBr: Ce crystals: Fast, efficient and high-energy-resolution scintillators[J]. Nucl Instrurn Methods, 2002, A486:254. 被引量:1
  • 8Alan Owens, et al. The hard X-ray response of Ce-doped lanthanum halide seindllators[J]. Nucl. Instr. and Meth. , 2007, A574.158-162. 被引量:1
  • 9R. Pard, et al. LaBr3 :Ce scintillation gamma camera prototype for X and gamma ray imaging[J]. Nucl. Instr. and Meth. A(2007), doi:10. 1016/ j. nirna. 2007. 01. 111. 被引量:1
  • 10Surti S, et al. Investigation of lanthanum scintillators for 3-D PET[J]. IEEE Trans Nucl. Sci , 2003, 50(3) :348-354. 被引量:1

共引文献63

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部