摘要 为了准确自动地调控养殖水体的溶解氧含量,提高水产养殖的自动化水平,解决养殖水域缺氧与增氧的问题,开发设计了一种基于工业自动化控制的PLC鱼塘自动增氧监控系统。该增氧控制系统的成功开发,有效地解决了农业鱼塘规模化养殖供氧问题,提升整个鱼塘水体的质量以及鱼的生存质量,减少鱼病发生,促进高产增产。 In order to accurately control the dissolved oxygen content of aquaculture water and improve the ability of automatic aquiculture,this article developed a PLC automatic oxygen-adding monitoring system based on industrial automation.This system effectively solves the problem of oxygen supply of intensive farms.Meanwhile,it improves the entire water quality and the life quality of fish,so that fish disease is reduced and the yield of fish is increased.
出处 《机械工程与自动化》 2018年第1期163-165,共3页 Mechanical Engineering & Automation
基金 广东省省级科技计划项目(2016A070715002)
关键词 传感器 信号采集 监控 增氧控制系统 sensor signal acquisition monitoring oxygen control system
  • 相关文献

参考文献5

二级参考文献23

  • 1解敏丽,周成.覆膜电极溶解氧测定仪示值误差的检定及影响因素[J].化学分析计量,2009,18(1):69-71. 被引量:2
  • 2洪江星,陈天文,李伟,庄峙厦.溶胶—凝胶法制备基于荧光猝灭原理的光纤氧传感器在线监测水中溶解氧[J].福建分析测试,2002,11(2):1541-1544. 被引量:6
  • 3张有德 涂时亮.MCS-51单片机实用子程序及其应用[M].上海:复旦大学出版社,1988.. 被引量:1
  • 4刘德福 孙淑嫒 任晓玲.碘量法测定溶解氧有关问题的探讨.河北省环境科学与技术,1986,(04):21-23. 被引量:1
  • 5Irja H, Lauri J, Martin V, et al. Micro-Winkler titration method for dissolved oxygen concentration measurement [J]. Analytica Chemicals Acta, 2009, 648(2): 167-173. 被引量:1
  • 6Burkhard H, Juan C A, Manuel M, et al. A multisyringe flow injectionWinkler-based spectrophotometric analyzer for in-line monitoring of dissolved oxygen in seawater [J]. Talanta, 2010, 80(3):1 341 -1 346. 被引量:1
  • 7Sahoo P, Ananthanarayanan R, Malathi N, et al. Pulsating potentiometric titration technique for assay of dissolved oxygen in water at trace level[J]. Analytica Chimica Ac- ta, 2010, 669(1-2): 17-24. 被引量:1
  • 8Kwang E C, Esther H L, Michael S D, et al. Measurement of Dissolved Oxygen in Water Using Glass-Encapsulated Myoglobin[J]. Anal. Chem., 1995,67(9) : 1 505 - 1 509. 被引量:1
  • 9Lee J H, Lira T S, Seo Y, et al. Needle-type dissolved oxygen mieroelectrode array sensors for in situ measure- ments[J]. Sensors and Actuators B, 2007, 128:179 - 185. 被引量:1
  • 10Lira T S, Lee J H, Papautsky I. Effect of recess dimen-sions on performance of the needle-type dissolved oxy- gen microelectrode sensor[J]. Sensors and Actuators B, 2009, 141(1): 50-57. 被引量:1

共引文献22

同被引文献2

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部