摘要 并网逆变器作为电能变换的重要一环,其控制算法显得尤为重要。针对单相L型并网逆变器将模型电流控制应用其中,得到了一种参数易于整定的逆变并网控制算法且适用性强。为满足工程实践要求,分析了数字控制延时对系统稳定性的影响,并给出了控制参数修正方法;同时在计算并网逆变器给定输出电压时,对于数字控制延时的影响给出了电网电压反馈值合适的相位补偿。最后通过仿真与实验验证了模型电流控制的适用性及补偿数字控制延时影响的有效性。 The control algorithm of grid-connected inverter is particularly important in power conversion.The model based current control to the single-phase grid-connected inverter with L-type filter is applied.A kind of control algo- rithm which is easy to set parameters is obtained and its applicability is strong.The influence of digital control delay on the stability of the system is analyzed and the control parameters are modified.Meanwhile, the appropriate phase compensation of the grid voltage feedback value is given in order to overcome the digital control delay,Finally ,the applicability of the model based current control and the correctness of the influence of the digital control delay on the system are verified by simulation and experiment.
机构地区 西北工业大学
出处 《电力电子技术》 CSCD 北大核心 2018年第1期43-46,共4页 Power Electronics
关键词 逆变器 模型电流控制 单相并网 数字控制延时 inverter model based current control single-phase grid-connected digital control delay
  • 相关文献

参考文献2

二级参考文献44

  • 1刘飞,段善旭,查晓明.基于LCL滤波器的并网逆变器双环控制设计[J].中国电机工程学报,2009,29(S1):234-240. 被引量:78
  • 2张承慧,叶颖,陈阿莲,杜春水.基于输出电流控制的光伏并网逆变电源[J].电工技术学报,2007,22(8):41-45. 被引量:76
  • 3张兴,张崇巍.PWM整流器及其控制[M].北京:机械工业出版社.2012. 被引量:150
  • 4陈瑶,金新民,童亦斌.三相电压型PWM整流器网侧LCL滤波器[J].电工技术学报,2007,22(9):124-129. 被引量:61
  • 5LINDGREN M, SVENSSON J. Control of a voltage-source converter connected to the grid through an LCL-filter-application to active filtcring[C]// Proceedings of the 29th Annual IEEE Power Electronics Specialists Conference, May 17-22, 1998, Fukuoka, Japan: 229- 235. 被引量:1
  • 6ZUEA O, CHANDRA A. Simulation and stability analysis of a 100 kW grid connected LCL photovoltaic inverter for industry [C]// Proceedings of Power Engineering Society General Meeting, June 18-22, 2006, Montreal, Canada. 被引量:1
  • 7WANG T C Y, YE Z H, SINHA G, et al. Output filter design for a grid interconnected three-phase inverter[C]// Proceedings of IEEE 34th Annual Power Electronics Specialist Conference, June 15-19, 2003, Mexico: 779-784. 被引量:1
  • 8LISERRE M, DELL' AQUILA A, BLAABJERG F. Stability improvements of an LCL-filter based three-phase active rectifier [C]// Proceedings of IEEE 33rd Annual Power Electronics Specialists Conference, June 23-27, 2002, Cairns, Australia: 1195-1201. 被引量:1
  • 9WU E, LEHN P W. Digital current control of a voltage source converter with active damping of LCL resonance[J]. IEEE Trans on Power Electronics, 2006, 21(5): 1364-1373. 被引量:1
  • 10TWINING E, HOLMES D G. Grid current regulation of a three-phase voltage source inverter with an LCL input filter [J]. IEEE Trans on Power Electronics, 2003, 18 (3):888-895. 被引量:1