基于ARM小电流接地故障选线装置

The Line Selection Device for Non-effectively Grounded System Faults Based on ARM
下载PDF
导出
摘要 小电流接地系统最常见的故障是单相接地故障。选线装置的硬件电路主要有采样模块、主控制模块及人机接口模块三个部分组成,分别采用32位ARM Cortex-M3 STM32f2和8位STM8S207S8微控制器芯片作为采样模块、主控制模块、人机接口模块的核心控制单元。选线装置的软件程序主要有主控制模块程序、人机接口模块程序、定时采样子程序、故障判断子程序等。现场运行结果表明,该装置运行稳定,能够正确地快速选线。 The most common failure of non-effectively groundedsystem is the single-phase-to-ground fault. The hardware circuitof the line selection device is mainly composed of such threeparts as sampling module, main control module and hu-man-computer interface module, respectively using 32-bit ARMCortex -M3 STM32f2 and 8-bit STM8S207S8 microcontrollerchips as the core control units of the three parts. The softwareprogram of the line selection device mainly consists of main con-trol module program, human-machine interface module program,timing sampling subroutine, fault judgment subroutine and so on.Field operation results show that the device is stable and can re-alize fast and correct line selection.
作者 方飞 徐丽萍
出处 《科教文汇》 2018年第2期181-183,共3页 Journal of Science and Education
基金 安徽三联学院校级自然科学研究项目"基于ARM小电流接地选线系统的设计"(编号:2014Z014) 安徽三联学院校级自然科学研究项目"自动化立体仓库拣选作业路径优化"(编号:2013Z016)
关键词 小电流接地系统 单相接地故障 ARM non-effectively grounded system single-phase-to-ground fault ARM
  • 相关文献

参考文献4

  • 1要焕年,曹梅月著..建筑电气安装工程施工图集 上 电动机安装施工说明及竣工验收规定 TX10[M].北京:中国电力出版社,2000:4.
  • 2陈德树主编..计算机继电保护原理与技术[M].北京:水利电力出版社,1992:172.
  • 3丁磊..小电流接地系统单相接地选线与定位技术的研究[D].山东大学,2004:
  • 4蔡润溟..小电流接地系统单相接地故障选线和测距方法的研究[D].山东大学,2007: