本文中作者以变压器损耗为基础,推导出大功率、高压、高频变压器的最大设计容量及合理设计频率的表达式。并通过实例验证了理论分析的正确性。
Based on the losses of high-power, high-voltage and high-frequency transformer, the expressions of the maximum design capacity and optimized frequency are deduced. The effectiveness of the theoretical analysis is verified by example.
出处
《变压器》
北大核心
2017年第12期15-19,共5页
Transformer
关键词
高频变压器
最大设计容量
合理设计频率
High frequency transformer
Maximum design capacity
Optimized frequency