期刊文献+

非接触式心率检测方法的颜色空间选择 被引量:2

Color Space Selection of Non-contact Heart Rate Measurement
下载PDF
导出
摘要 采用非接触式方法进行人体心率检测,较传统接触式的测量方法更加便捷舒适。基于图像光学容积(iPPG)的非接触式心率测量方法,简要分析该方法的实现流程及颜色空间产生测量误差的机理,设计实验来对比不同颜色空间的测量误差,一方面证明了在非接触式心率测量过程中进行颜色空间选取的必要性,另一方面获得了可用以提高心率测量精度的最优颜色空间。实验结果表明,与同一时刻采用心电测量仪(ECG)得到的心率相比,采用RGB颜色空间进行心率测量的误差最小,实验的平均误差达到1.68bpm。因此,在非接触式心率测量中选择RGB颜色空间可以达到更高的精度。 Compared with the traditional contact measurement method,the non-contact method for heart rate detection is more convenient and comfortable.Based on the non-contact heart rate measurement method of image-photoplethysmography (iPPG),this paper briefly analyzed the mechanism of this method and the measurement error of color space.The experiment compares the measurement error according to the different color space,which proves the necessity of selecting the color space during the non-contact heart rate measurement.On the other hand,optimal color space can be used to improve the accuracy of heart rate measurement accuracy of the color space.The experimental results show that the heart rate measurement with RGB color space has the smallest error compared with the heart rate obtained by electrocardiograph (ECG) at the same time.The average error of experiment is 1.68 bpm.Thus,choosing RGB color in non-contact heart rate measurement space can get higher accuracy.
机构地区 江西中医药大学
出处 《计算机科学》 CSCD 北大核心 2017年第B11期260-262,301,共4页 Computer Science
基金 江西中医药大学校级课题(2014jzzdxk021 2014jzyb-3 2016jzgy-06)资助
关键词 颜色空间 非接触 心率 图像容积 Color space Non-contact Heart rate Image-photo plethysmography
  • 相关文献

参考文献5

二级参考文献49

  • 1Droitcour AD,Boric-Lubecke O,Libecke VM,et al.0.25μm CMOS and BiCMOS Single-chip Direct-conversion Doppler Radars for Remote Sensing of Vital Signs[C].2002 ISSCC Digest.2002 (1):348 被引量:1
  • 2AOYAGI T, FUSE M, KOBAYASHI N, et al. Multiwave- length pulse oximetry: theory for the future [J]. Anesth Analg, 2007, 105(6 Suppl): S53-S58. 被引量:1
  • 3WIERINGA F P, MASTIK F, VAN DER STEEN A F. Contactless multiple wavelength photoplethysmographic ima- ging: a first step toward "SpO2 camera" technology[J]. Ann Biomed Eng, 2005, 33(8) : 1034-1041. 被引量:1
  • 4SUN Y, PAPIN C, AZORIN-PERIS V, et al. Use of ambi- ent light in remote photoplethysmographic systems., compari- son between a high-performance camera and a low-cost web- cam[J]. J Biomed Opt, 2012, 17(3) :037005. 被引量:1
  • 5NONNENMACHER A, HOPP H, DUDENHAUSEN J. Predictive value of pulse oximetry for the development of fetal acidosis[J]. J Perinat Med, 2010, 38(1): 83-86. 被引量:1
  • 6EWER A K, MIDDLETON L J, FURMSTON A T, et al. Pulse oximetry screening for congenital heart defects in new- born infants (PulseOx) : a test accuracy study[J]. Lancet, 2011, 378(9793) : 785-794. 被引量:1
  • 7WAGNER J L, RUSKIN K J. Pulse oximetry: basic princi- ples and applications in aerospace medicine[J]. Aviat Space Environ Med, 2007, 78(10): 973-978. 被引量:1
  • 8CHUNG F, LIAO P, ELSAID H, et al. Oxygen desatura- tion index from nocturnal oximetry: a sensitive and specific tool to detect sleep-disordered breathing in surgical patients [J]. Anesth Analg, 2012, .114(5) : 993-1000. 被引量:1
  • 9YAN Y S, POON C C, ZHANG Y T. Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution[J]. J Neuroeng Rehabil, 2005, 2(1): 3. 被引量:1
  • 10FOO J Y, WILSON S J. A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states[J]. Med Biol Eng Comput, 2006, 44 (1-2) : 140-145. 被引量:1