基于色谱分析技术的航天器热管检漏方法研究 被引量:2

STUDY OF THE LEAK DETECTION OF SPACECRAFT HEAT PIPE BASED ON THE GAS CHROMATOGRAPHY
下载PDF
导出
摘要 针对航天器热控系统中热管的高密封性能要求,以及特殊的传热工质,分析现存检漏方法存在的问题,提出使用色谱分析技术对热管进行检漏。介绍了基于色谱技术的热管检漏工作原理,检漏系统设计,试验方法和数据处理等,并对工质为乙烷的气液两相、漏率在10^(-8)Pa·mμ/s量级的热管进行检漏,为将来热管以及示漏物质是特殊工质的被检件检漏工作提供参考。 In this paper,the high sealing performance of heat pipe in spacecraft thermal control system is required,and a lot of study on leak detection of the heat pipe whose working medium is special heat transfer medium are carried out. For solving this question,the existing leak detection methods are analyzed. The leak detection of heat pipe based on chromatographic analysis technique is introduced. This paper introduces the working principle of leak detection of heat pipe using chromatographic technique,the design of the leak detection experiment system,experimental method data processing method. The heat pipe whose working medium is gas-liquid two phase flow of C_2H_6 is leak tested,its leakage rate is in the order of 10-8 Pa·m^3/s,that provides a reference for the future of the heat pipe leaking detection.
出处 《真空与低温》 2017年第5期280-284,共5页 Vacuum and Cryogenics
基金 国家自然科学基金(U1537109)
关键词 热管 色谱技术 系统设计 试验方法 heatpipe chromatographytechnique systemdesign experimentalmethod
  • 相关文献

参考文献4

二级参考文献20

  • 1肖祥正,闫荣鑫,赵忠,张家珠,吴孝俭.运载火箭三子级燃料箱体快速检漏技术的研究[J].航天器环境工程,1995,12(4):17-23. 被引量:5
  • 2闫荣鑫,肖祥正,赵忠,张家珠.温度变化对漏孔漏率的影响[J].真空与低温,1995,1(1):12-15. 被引量:4
  • 3陈旭,张启亮,刘亲旻,等.正压漏孔漏率校准装置的研制[C]∥第十届全国质谱分析和检漏会议论文集.中国真空协会质谱与检漏专业委员会,2003:28-33. 被引量:3
  • 4于红燕.正压漏孔校准方法研究[C]∥第十三届全国质谱分析和检漏会议论文集.沈阳:中国真空协会质谱与检漏专业委员会,2005:31-36. 被引量:2
  • 5U. W lchli, A. stckli, M. A. B sch, A. SCHMID. Fundamental Leak Calibration System for Gas Leaks with A Defined Pressure Difference over the leak Element. J. Vac. Sci. Technol. , 1996, A14 ( 3 ) : 1247 ~ 1251. 被引量:1
  • 6Karl Jousten and Ute Becker. A primary standard for the calibration of sniffer test leak devices. Metrologia, 46 (2009) :560 - 568. 被引量:1
  • 7GJB3756-99测量不确定度的表示与评定[S]. 被引量:5
  • 8冯焱,张涤新.恒压式正压漏孔校准装置的设计[J].真空科学与技术学报,2007,27(5):442-445. 被引量:11
  • 9王金锁,许红,胡央丽,等.正压漏孔校准装置的研制[J].真空科学与术学报,2004,24(6):439-441. 被引量:1
  • 10Karl Jousten, Ute Becker. A primary standard for the calibra- tion of sniffer test leak devices[J]. Metrologia, 2009, 46 (5) : 560-568. 被引量:1

共引文献34

同被引文献20

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部