期刊文献+

Comparison of Space Glucose Control and Routine Glucose Management Protocol for Glycemic Control in Critically Ⅲ Patients: A Prospective, Randomized Clinical Study 被引量:4

Comparison of Space Glucose Control and Routine Glucose Management Protocol for Glycemic Control in Critically Ⅲ Patients: A Prospective, Randomized Clinical Study
原文传递
导出
摘要 Background:The Space Glucose Control (SGC) system is a computer-assisted device combining infusion pumps with the enhanced Model Predictive Control algorithm to achieve the target blood glucose (BG) level safely.The objective of this study was to evaluate the efficacy and safety of glycemic control by SGC with customized BG target range of 5.8-8.9 mmol/L in the critically ill patients.Methods:It is a randomized controlled trial of seventy critically ill patients with mechanical ventilation and hyperglycemia (BG 〉 9.0 mmol/L).Thirty-six patients in the SGC group and 34 in the routine glucose management group were observed for three consecutive days.Target BG for both groups was 5.8-8.9 mmol/L.The primary outcome was the percentage time in the target range.Results:The percentage time within BG target range in the SGC group (69 ± 15%) was significantly higher than in the routine management group (52 ± 24%;P 〈 0.01).No measurement was 〈2.2 mmol/L,and there was only one episode of hypoglycemia (2.3-3.3 mmol/L) in each group.The average BG was significantly lower in the SGC group (7.8 ± 0.7 mmol/L) than in the routine management group (9.1 ± 1.6 mmol/L,P 〈 0.001).Target BG level was reached earlier in the SGC group than routine management group (2.5 ± 2.9 vs.12.1 ± 15.3 h,P =0.001).However,the SGC group performed worse for daily insulin requirement (59.8 ± 39.3 vs.28.4 ± 36.7 U,P =0.001)and sampling interval (2.0 ± 0.5 vs.3.7 ± 0.5 h,P 〈 0.001) than the routine management group did.Multiple linear regression showed that the intervention group remained a significant individual predictor (P 〈 0.001) of the percentage time in target range.Conclusions:The SGC system,with a BG target of 5.8-8.9 mmol/L,resulted in effective and reliable glycemic control with few hypoglycemic episodes in critically ill patients with mechanical ventilation and hyperglycemia.However,the workload was increased Background:The Space Glucose Control (SGC) system is a computer-assisted device combining infusion pumps with the enhanced Model Predictive Control algorithm to achieve the target blood glucose (BG) level safely.The objective of this study was to evaluate the efficacy and safety of glycemic control by SGC with customized BG target range of 5.8-8.9 mmol/L in the critically ill patients.Methods:It is a randomized controlled trial of seventy critically ill patients with mechanical ventilation and hyperglycemia (BG 〉 9.0 mmol/L).Thirty-six patients in the SGC group and 34 in the routine glucose management group were observed for three consecutive days.Target BG for both groups was 5.8-8.9 mmol/L.The primary outcome was the percentage time in the target range.Results:The percentage time within BG target range in the SGC group (69 ± 15%) was significantly higher than in the routine management group (52 ± 24%;P 〈 0.01).No measurement was 〈2.2 mmol/L,and there was only one episode of hypoglycemia (2.3-3.3 mmol/L) in each group.The average BG was significantly lower in the SGC group (7.8 ± 0.7 mmol/L) than in the routine management group (9.1 ± 1.6 mmol/L,P 〈 0.001).Target BG level was reached earlier in the SGC group than routine management group (2.5 ± 2.9 vs.12.1 ± 15.3 h,P =0.001).However,the SGC group performed worse for daily insulin requirement (59.8 ± 39.3 vs.28.4 ± 36.7 U,P =0.001)and sampling interval (2.0 ± 0.5 vs.3.7 ± 0.5 h,P 〈 0.001) than the routine management group did.Multiple linear regression showed that the intervention group remained a significant individual predictor (P 〈 0.001) of the percentage time in target range.Conclusions:The SGC system,with a BG target of 5.8-8.9 mmol/L,resulted in effective and reliable glycemic control with few hypoglycemic episodes in critically ill patients with mechanical ventilation and hyperglycemia.However,the workload was increased
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第17期2041-2049,共9页 中华医学杂志(英文版)
关键词 Critical Illness: Glucose Control in Intensive Care HYPERGLYCEMIA Space Glucose Control Enhanced Model Predictive Control Critical Illness: Glucose Control in Intensive Care Hyperglycemia Space Glucose Control Enhanced Model Predictive Control
  • 相关文献

同被引文献41

引证文献4

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部