台州市生活污水处理厂设计水量中雨水混入比例研究 被引量:12

Study of rainwater mixing rate of design water quantity at domestic sewage treatment plants in Taizhou City
下载PDF
导出
摘要 基于台州市椒江区2014年污水处理厂进水量和雨量监测站的数据,进行污水处理厂日进水量频率分析和城镇污水管网中雨水混入比例分析,从而对污水处理厂设计水量进行修正。结果表明:小雨、中雨、大雨、连续暴雨时的污水量分别是晴天污水量的1.29、1.53、1.77、2.31倍;地下水与河水渗入量约占晴天日均污水量的24.1%,雨天雨水混入量约占雨天日均污水量的24.2%;随着降雨量增大,雨水混入比例由10%升高至35%,最后趋于27%;滨海城市生活污水处理厂设计水量中雨水混入比例可定为25%~30%。 Based on the data of inflow of a sewage plant and data from rainfall monitoring stations in the Jiaojiang District, in Taizhou City in 2014, we analyzed the daily inflow frequency at the sewage plant and the rainwater mixing rate in urban sewage pipe networks, so as to modify the design water quantity of the sewage plant.The results are as follows: the sewage quantities in the cases of light, moderate, heavy, and continuously heavy rainfall were respectively 1.29, 1.53, 1.77, and 2.31 times those on sunny days.The quantity of groundwater mixed in sewage accounted for 24.1% of the daily sewage quantity on sunny days, and the quantity of rainwater mixed in sewage accounted for 24.2% of the daily sewage quantity on rainy days.With the increase of rainfall, the rainwater mixing rate increased from 10% to 35%, and finally tended to be 27%.The rainwater mixing rate of the design water quantity for sewage plants in coastal cities can be determined as a value ranging from 25% to 30%.
出处 《水资源保护》 CAS CSCD 2017年第4期75-79,94,共6页 Water Resources Protection
基金 国家自然科学基金(51579071 51379061) 霍英东教育基金(141073) 江苏省自然科学基金(BK20131370)
关键词 雨水混入比例 入渗流量 设计水量 污水处理厂规模 rainwater mixing rate infiltration flow design water quantity sewage plant scale
  • 相关文献

参考文献23

二级参考文献98

共引文献132

同被引文献132

引证文献12

二级引证文献145

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部