期刊文献+

多回波肝脏内插容积激发评价水脂模型脂肪含量的可行性 被引量:3

Feasibility of multi echo liver interpolated volume excitation in the quantification of fat content
下载PDF
导出
摘要 目的:利用水脂混合液模型评估多回波肝脏内插容积激发(mLIVE)技术定量分析脂肪含量的可行性和准确性。方法:制作水脂混合液模型,脂肪含量(容积比)分别为5%、10%、15%、20%、30%和40%,在国产超导1.5 T磁共振下用mLIVE序列测定模型脂肪含量,对测得的结果和真实脂肪含量做线性回归分析,分析两者相关性。以实际脂肪含量为标准,采用Bland-Altman散点图得出mLIVE测量值差值的95%可信区间的一致性界限,评估两者一致性。结果:mLIVE测得的脂肪含量和真实脂肪含量具有高度正相关关系(线性回归方程为y=0.810 6x+0.304 9,r^2=0.998 8,F=322 3,P=0.000)。Bland-Altman散点图得到的mLIVE测量值与实际脂肪含量差值的95%可信区间为-1.4%~8.4%。结论:mLIVE定量评价水脂模型中脂肪含量是可行的。 Objective To validate the feasibility and accuracy of multi echo liver interpolated volume excitation (mLIVE) in the quantification of fat content using fat-water mixture model.Methods Fat-water mixture phantom consisting of known fat fractions (v/v) of 5%,10%,15%,20%,30% and 40%,respectively,were established.The fat content of the established phantom were examined using mLIVE on a domestic 1.5 T magnetic resonance scanner.The relationships between measured fat fractions and known fat fractions were assessed using linear regression analysis,Taking the known fat fractions as the standards,we applied Bland-Altman map to obtain the consistency boundary of 95% confidence interval (95% CI) of the differences between measurements and known values and to assess their consistency.Results The fat fractions measured using mLIVE had a highly positive correlation with known fat-fractions (y=0.810 6x+0.304 9,r^2=0.998 8,F=3 223,P=0.000).According to Bland-Altman map,the 95%CI of differences between the results measured with mLIVE and known fat fraction ranged from-1.4% to 8.4%.Conclusion mLIVE can be used to quantify the fat content of fat-water mixture phantoms.
作者 李振玉 王娟 刘斌 彭保成 马园 LI Zhenyu WANG Juan LIU Bin PENG Baocheng MA Yuan(Xinxiang Central Hospital, Xinxiang 453000, Chin)
机构地区 新乡市中心医院
出处 《中国医学物理学杂志》 CSCD 2017年第5期468-471,共4页 Chinese Journal of Medical Physics
关键词 多回波肝脏内插容积激发 磁共振成像 脂肪 对比研究 multi echo liver interpolated volume excitation magnetic resonance imaging fat comparative examination
  • 相关文献

参考文献2

二级参考文献29

  • 1范明霞,田建明,陆建平.肝脏病变活体MR波谱研究进展[J].中华放射学杂志,2004,38(7):771-773. 被引量:12
  • 2van Werven JR, Marsman HA, Nederveen A J, et al. Assessment of hepatic steatosis in patients undergoing liver resection: comparison of US, CT, Tl-weighted dual-echo MR imaging, and point-resolved IH MR spectroscopy[J]. Radiology, 201 O, 256(1): 159-168. 被引量:1
  • 3Dixon WT. Simple proton spec:troscopic imaging[J]. Radiology, 1984, 153(1):189-194. 被引量:1
  • 4Hines CD, Yu H, Shimakawa A, et al. TI independent. '1'2" corrected MRI with accurate spectral modeling tor quantification of fat: validation in a fat-water-SPIO phantom [J].J M agn Reson hnaging, 2009, 30(5): 1215-1222. 被引量:1
  • 5Bydder M, Yokoo T, Hamilton G, et al. Relaxation effects in the quantification of fat using gradient echo imaging[J].Magn Reson hnaging, 2008, 26(3):347-359. 被引量:1
  • 6Bernard CP, Liney GP, Manton DJ, et al. Comparison of fat quantification methods: a phantom study at 3.0T[J].J Magn Reson Imaging, 2008, 27(1 ): 192-197. 被引量:1
  • 7Li X, Kuo D, Schafer AL, et al. Quantification of vertebral bone marrow fat content using 3 Tesla MR spectroscopy: reproducibility, vertebral variation, and applications in osteoporosis. J Magn Reson Imaging, 2011, 33(4): 974-979. 被引量:1
  • 8Reeder SB, Cruite I, Hamilton G, et al. Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy. J Magn Reson Imaging, 2011, 34(4): 729-749. 被引量:1
  • 9Alizai H, Nardo L, Karampinos DC, et al. Comparison of clinical semi-quantitative assessment of muscle fat infiltration with quantitative assessment using chemical shift-based water/fat separation in MR studies of the calf of post-menopausal women. Eur Radiol, 2012, 22(7): 1592-1600. 被引量:1
  • 10Oei L, Rivadeneira F, Zillikens MC, et al. Diabetes, diabetic complications, and fracture risk. Curt Osteoporos Rep, 2015, 13(2): 106-115. 被引量:1

共引文献40

同被引文献17

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部