摘要
目的研究多层螺旋CT三维重建技术对骨盆骨折患者的应用效果。方法对76例骨盆骨折患者应用X射线摄片以及多层螺旋CT三维重建技术进行诊断,比较两种影像检查技术应用效果。结果x射线诊断法对骨盆骨折患者诊断准确性显著低于多层螺旋CT三维重建法(P〈0.05);两种方法对骨盆骨折患者骨折部位诊断结果比较差异无统计学意义(P〉0.05);多层螺旋CT三维重建技术对骨盆骨折诊断敏感度为100%,显著高于X射线诊断法的59.2%(P〈0.05)。结论多层螺旋CT三维重建技术有效弥补了x线DR不足之处,CT重建更加清晰立体,能够按照实际需求从各个方位展现骨盆骨折情况,对合理指导临床诊断、提高手术成功率具有重要意义。
Objective To study the effects of MSCT 3D reconstruction applying to pelvic fracture patients. Methods 76 cases of pelvic fracture patients were selected and given X ray and MSCT 3D reconstruction. Application effect of the two methods were compared. Results The accuracy of X ray technology was obviously lower than MSCT 3D reconstruction (P〈0.05) ; The results of both technologies applying to the fracture parts showed no statistical significance (P〉0.05) ; The pelvic fracture diagnosis sensitiveness for MSCT 3D reconstruction was 100G which was obviously higher than X ray's 59.2% (P〈0.05). Conclusion MSCT 3D reconstruction can effectively make up the deficiency that X ray and DR have. CT reconstruction is clearer and more stereo. It can reveal the pelvic condition in all aspects based on the actual demand. Thus, it plays an important role in reasonably directing the clinical diagnosis and improving the successful rate of operation.
出处
《临床心身疾病杂志》
CAS
2017年第4期153-155,共3页
Journal of Clinical Psychosomatic Diseases