摘要
介绍56 000 m^3/h空分装置前后4次因为空气压缩机轴位移升高而停车的情况及检修发现的问题,分析导致空气压缩机轴位移上升的原因,并提出相应的防范措施。
In an air separation unit with capacity of 56 000 m^3/h,trips happened four times because of the increase in air compressor axial displacement.Reasons were analyzed during maintenance,and precaution measures were presented.
出处
《大氮肥》
CAS
2017年第2期106-110,共5页
Large Scale Nitrogenous Fertilizer Industry
关键词
空气压缩机
轴位移
润滑油
气封
静电腐蚀
air compressor
axial displacement
lubricant oil
air seal
static corrosion