摘要 目的探讨超声心动图与动态心电图诊断冠心病合并心力衰竭的价值.方法选取60例冠心病合并心力衰竭患者作为研究组,同时选取60例单纯冠心病患者作为对照组.全部患者均采用超声心动图与动态心电图检查.结果研究组LVESD、LVEF、LVFS、SV、E/A与ET均明显低于对照组,LVEDD、ICT、IRT均明显高于对照组,2组比较差异具有统计学意义(P<0.05);研究组SDNN、SDANN、r MSSD均明显低于对照组,研究组HR明显高于对照组,2组比较差异具有统计学意义(P<0.05),研究组ST-T波改变、T波低平或平坦所占比例明显高于对照组(P<0.05);以冠脉血管造影(CAG)结果作为金标准,设定LVEF<50%作为超声心动图诊断阳性标准,设定SDNN<100 ms作为动态心电图的诊断阳性标准,2种检查方法在诊断灵敏度、特异度与准确度的比较差异无统计学意义(P>0.05).结论 LVESD、LVEDD、LVEF、SV、E/A、ET等超声心动图参数与SDNN、SDANN、r MSSD等心电图参数在诊断冠心病合并心力衰竭中均具有重要的价值. Objective To study the value of ultrasonic cardiogram and dynamic electrocardiogram in diagnosis of coronary heart disease with heart failure. Methods 60 cases of patients with coronary heart disease with heart failure were selected as study group, and another 60 cases of patients with coronary heart disease were selected as control group. All patients were given echocardiography and dynamic electrocardiogram examination. Results LVESD, LVEF, LVFS, SV, E/A and ET of study group were significantly lower than those of control group, LVEDD, ICT, IRT significantly higher than those of control group, and the differences had statistically significant difference (P 〈 0.05) . SDNN, SDANN rMSSD of study group were significantly lower than control group, HR in study group were significantly higher than control group and the differences were statistically significant (P 〈 0.05) . ST - T wave changes, T wave low proportion of study group were significantly higher than those of the control group (P 〈 0.05) With CAG results as the gold standard, LVEF 〈 50% as echocardiography positive diagnosis standard, and SDNN〈100 ms as dynamic electrocardiogram positive diagnosis standard, difference between the two methods in terms of sensitivity, specific and accuracy had no statistically significance (P 〉 0.05) .Conclusion Ultrasonic cardiogram parameters such as LVESD, LVEDD, LVEF, SV, E/A, ET and echocardiographvparameters such as SDNN, SDANN rMSSD are of great importance in the diagnosis of coronary heart disease with heart failure.
作者 叶学群 聂磊
出处 《昆明医科大学学报》 CAS 2017年第2期95-98,共4页 Journal of Kunming Medical University
基金 新疆维吾尔自治区科技计划项目(Y121310012)
关键词 超声心动图 动态心电图 诊断 冠心病 心力衰竭 Echocardiography Dynamic electrocardiogram Diagnosis Coronary heart disease Heartfailure
  • 相关文献

参考文献12

二级参考文献90

  • 1季晓平,张运,鹿庆华,李大动.六种超声方法估测左室射血分数的准确性比较[J].中华超声影像学杂志,1995,4(1):12-14. 被引量:15
  • 2丁建东,陆凤翔,马根山,许迪,孔祥清,陈莉,雍永宏,周蕾,杨荣,盛燕辉.房间隔缺损封堵术后右心室功能的变化[J].中国介入心脏病学杂志,2005,13(5):296-298. 被引量:7
  • 3Dodge HT. The use of biplane angiocardiography for the measurement of LV volume in man[J]. Am Heart J,1960,60:762. 被引量:1
  • 4Sandier H,et al. The use of single plane angiocardiograms for the caculation of LV volume in man[J]. Am Heart J,1968,75:352. 被引量:1
  • 5Jenessesaux C, Metz D, Malllier B,et al. Estimation of with acoustic quantification in myocardial infarction. Comparisonwith echo cardiograpgic, angiographic and scintigraphic data[J]. Arch Mal Coeur Vaiss, 1996,89(7) :843 - 849. 被引量:1
  • 6Takenaka A, Iwass M, Sobue T, et al. The discrepancy between echocardiograpgic, cineventriculography and thermodflution. Evaluafion of left ventricular volume and ejection fraction[J]. Int J Card Imaging,1995,11 (4) :255 - 262. 被引量:1
  • 7Muller X, Stauffer JC, Jaussi A,et al. Subjective visualechoeardiograpgic estimate of left ventricular ejection fraction as a alternative to conventional echocardiograpgic methods: Comparison with contrast angiography[J]. Clin Cardiol, 1991,14(11) :898 - 902. 被引量:1
  • 8Tsujita KY, Zhang G, Sumita Y, et al. Validity and reproducibility of echocardiograpgic measurement of left ventricular ejection fraction by acoustic quantification with tissue harmonic imaging technique[J]. J Am Soc Echocardiogr, 2000,13 (4) : 300 - 305. 被引量:1
  • 9Nahar T, Croft L, Shapiro R, et al. Comparison of four echecardiograpgic technique. For measuring left ventricular ejection fraction[J]. Am J Cardiol,2000,86(12) :1358 - 1362. 被引量:1
  • 10Schwaez KQ, 13ezante GP, Chfn X, et al. Contrast harmoniccolor Doppler left ventriculography : Machine - interpreted left ventricular ejection fraction compared with equilibriumgated radionuclide ventriculography[J]. J Am Soc Echocardiogr, 2000,13 (5) : 368 - 0378. 被引量:1

共引文献148

同被引文献221

引证文献27

二级引证文献140

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部