摘要
实践中发现,使用国标和ASTM标准的转换值时常发生对应不上的情况,通过比较GB/T 1885-1998(04)与ASTM D1250-08(2013)e1的差异以及标准使用情况的差异,发现产生偏差的主要原因来自于GB/T1885-1998(04)中使用的表E2与其相应的表59A、表59B、表59D对应不上,文中对三组表换算的结果进行统计分析,并简要讨论了相关对策。
In the practice,it is found that using the national standard and ASTM standard to convert to different values. It is clear that the main reason for the deviation is from the Table E2 not corresponding with Table 59 A,59B and 59 C,by comparing the differences between ASTM D1250-08(2013)e1 and GB/T 1885-1998(04),and differences between standard usage,and statistical analysis was carried out on the results of the deviation,the relevant countermeasures are briefly discussed.
出处
《检验检疫学刊》
2017年第1期72-75,共4页
Journal of Inspection and Quarantine
关键词
进出口油品
密度换算
原油
产品
润滑油
Import and Export Oil
Density Conversion
Crude Oil
Products
Lubricating Oils