摘要
通过对上海地区23个地源热泵项目的测试和调研,得到了地源热泵系统夏季的制冷能效比和冬季的制热性能系数数据。按照建筑类型和建筑规模统计分析了地埋管地源热泵项目的系统性能,并计算了地源热泵常规能源替代量和经济环境效益,供类似项目参考。
The energy efficiency ratio of ground-source heat pump (GSHP) systems in summer, and the coefficient in winter, was obtained by testing 23 GSHP projects in areas with hot summers and cold winters. The coefficient of performance was analyzed. According to the architectural type and size of structures, calculations were done to estimate the contribution of ground source heat pumps to the quantity of conventional alternative energy, and to estimate the economic and environmental benefits of GSHP systems. This is expected to provide a reference for similar projects.
出处
《上海国土资源》
2016年第4期69-71,共3页
Shanghai Land & Resources
基金
中国地质调查局地调项目(水[2014]02-001-014-03)
关键词
地源热泵
性能系数
能效比
节能分析
ground-source heat pump
coefficient of performance
energy efficiency ratio