期刊文献+

钢绞线张拉过程中箱梁冷缝应力应变分析

Anchor Cable Tension in the Process of Cold Box Girder Joint Stress and Strain Analysis
下载PDF
导出
摘要 通过预应力锚索张拉过程中对冷缝位置处新旧混凝土应力应变值测读,比较每个测试位置两个测试点的应变和应力变化情况,分析箱梁冷缝处新旧混凝土的共同工作、协调变形能力,并用数理统计软件SPSS分析同区域两个测点的应变相关性,两者对比,以此判断冷缝处新旧混凝土协调变形能力。 To measure the stress and strain at the position of the cold joint between the new and old concrete by the pre-stressed anchor cable tensioning process,compare the strain and stress changes of two test points in each test position,analyze the interacting behavior and coordinated deformation ability of the new and old concrete in the cold joint of the box girder,and use SPSS,the mathematical statistics software to analyze the strain dependence of the two measurement points in the same area,on the basis of the comparison,judging the coordinated deformation ability of new and old concrete in cold joints.
作者 杨成 黄质宏 卢萍 璩泽君 YANG Cheng HUANG Zhihong LU Ping QU Zhejun(college of civil Engineering, Guizhou Universitg, Guiyang 550025 Chin)
出处 《贵州大学学报(自然科学版)》 2016年第6期89-92,140,共5页 Journal of Guizhou University:Natural Sciences
基金 贵州省科学技术基金项目(黔科合LH字[2015]7085号)
关键词 冷缝 箱梁 受力性能 cold joint box girder mechanical behavior
  • 相关文献

参考文献3

  • 1姚华.静载试验中有冷缝箱梁受力性能研究[J].黑龙江科技信息,2014(3):198-198. 被引量:1
  • 2杨维忠,张甜编著..SPSS统计分析与行业应用案例详解[M].北京:清华大学出版社,2013:412.
  • 3林丽..两组独立数据差异性统计检验方法及应用的研究[D].上海交通大学,2007:

二级参考文献5

  • 1JTGD62-2004.公路钢筋混凝土及预应力混凝土桥涵设计规范[S].[S].,.. 被引量:1844
  • 2JTGD60-2004.公路桥涵设计通用规范[S].[S].,.. 被引量:1583
  • 3铁组YC4-4/1978.大跨径混凝土桥梁的试验方法[S]. 被引量:2
  • 4沈薄生.混凝土结构设计[M].北京:高等教育出版社,2007,11. 被引量:2
  • 5GB/T50152-2012.混凝土结构试验方法标;隹[S]. 被引量:1