摘要 基于太阳电池联接失配问题的普遍性,利用太阳电池单二极管等效电路模型及二体模型分析法,并根据基尔霍夫电流定律和电压定律,推导出串联等效电路的电流、电压方程组。采用数值法得到两种情况下各个电流的数值解,同时采用相关的曲线详细分析和讨论这两种情况下各个电流变化特性,并且给出了这两种情况下的物理解释。分析表明这些参数对太阳电池串联内部电流分布影响很大。研究结果有助于分析太阳电池和系统的损失原因。 In view of the universality for the mismatch problem of solar cells connection, by using the equivalent one-diode circuit of solar cell and analysis of two-body model, two sedes solar cells were selected as research object. At first, the equations of current and voltage were deduced from electrical related laws. Then, the appropriate simulation parameters were selected. By using the reverse saturation current and the diode quality factor as the independent variables, respectively, the changing characteristics of each branch current in two series solar cells were numerically discussed and analyzed under these two cases for the first time. And simple physical explanation was provided for the modeling results. The analysis shows that those parameters have different impacts on the internal currents of solar cells connection in series. Meanwhile, the results will contribute to the better comprehending of the reason for efficiency loss of solar cells and systems.
出处 《电源技术》 CAS CSCD 北大核心 2017年第1期93-96,共4页 Chinese Journal of Power Sources
基金 国家自然科学基金资助项目(51561031) 广西自然科学基金资助项目(2015GXNSFBA139240) 广西高校复杂系统优化与大数据处理重点实验室开放基金项目(2015CSOBD0102) 博士科研启动基金(G20150001)
关键词 太阳电池 失配损失 内部电流 solar cells mismatch loss internal current
  • 相关文献

参考文献4

二级参考文献46

  • 1李大勇,陈如亮,崔岩,石德全.基于Pspice的光伏组件热斑现象仿真[J].哈尔滨工业大学学报,2006,38(11):1888-1892. 被引量:20
  • 2崔岩, 刘素梅. 基于Pspice的热斑现象解决方案[C].系统仿真及其应用学术交流会, 2006, 1888-1897. 被引量:2
  • 3M. C. Alonso-Garcia, J. M. Ruiz, F. Chenlo. Experimental study of mismatch and shading effects in the I-V characteristic of a photovoltaic module [J].Solar Energy Materials & Solar Cells, 2006, 90(3): 329-340. 被引量:1
  • 4M. Drif, P.J. Perez, J.Aguilera et al.. A new estimation method of irradiance on a partially shaded P-V generator in grid-connected photovoltaic systems[J].Renewable Energy, 2008, 33(9): 2048-2056. 被引量:1
  • 5Engin Karatepe, Mutlu Boztepe, Metin Colak. Development of a suitable model for characterizing photovoltaic arrays with shaded solar cells[J].Solar Energy, 2007, 81(8): 977-992. 被引量:1
  • 6张臻, 沈辉, 朱家劲 等. 太阳电池组件阴影遮挡问题实验研究[C]. 第十届中国太阳能光伏会议, 2008, 964-971. 被引量:2
  • 7Volker Quaschning, Rolf Hanitsch. Numerical simulation of current-voltage characteristic of photovoltaic systems with shaded solar cells[J].Solar Energy, 1996, 56(6): 513-520. 被引量:1
  • 8云志刚, 杨宏, 李文滋. 光伏组件中电池遮挡与I-V曲线特性变化关系[C].第八届全国光伏会议, 2004, 356-359. 被引量:3
  • 9刘宏. 非晶硅太阳电池遮挡性能的理论模型与测试实验[C]. 中国太阳能学会学术年会论文集, 2003, 366-369. 被引量:1
  • 10Achim Woyte, Johan Nijs, Ronnie Belmans. Partial shadowing of photovoltaic arrays with different system configurations: literature review and field test results[J].Solar Energy, 2003, 74(3): 217-233. 被引量:1