随着我国化工行业的不断发展,环境污染问题的逐渐加剧,化工厂排放的各类废水的处理工作已经越来越受到社会的关注和重视。其中消防废水是化工厂主要排放废水之一,其是在化工厂火灾消防工作中产生的,给环境带来的污染性较为严重。对化工厂消防废水氧化处理技术进行研究,以某化工厂为例采用模拟实验的方式,使用Fenton氧化法处理废水,并以五种投加量、氧化时间和反应pH值进行研究,获取最佳反应条件,以期能为相关工作提供参考。
With the continuous development of China' s chemical industry, environmental pollution problems gradually serious, for chemical plant emissions of various types ofwastewater treatment work has been more and more social attention and attention.The fire water is one of the main discharge wastewater in chemical plant, which is produced in the fire and fire control work of chemical plant, which brings serious pollution to the environment.Oxidation treatment of wastewater containing the following chemical plant fire in a chemical plant as an example, by means of simulation experiments using Fenton oxidation treatment of wastewater, and five kinds of dosage, oxidation time and reaction pH value were studied to obtain the optimal reaction conditions, in order to provide reference for relevant work.