期刊文献+

宝鸡地区成年健康人群血清胱抑素C参考区间调查 被引量:3

Investigation of Reference Range of Serum Cystatin C of Healthy People in Baoji
下载PDF
导出
摘要 目的:建立宝鸡地区成人血清胱抑素C(Cys-C)的参考区间。方法对健康成人男性720例、女性722例采集静脉血标本,采用颗粒增强散射免疫比浊法测定其血清 Cys-C的浓度。结果宝鸡地区健康成年人 Cys-C水平男性高于女性(t=11.625,P<0.05)。男性、女性 Cys-C 水平均随年龄升高而增高(男:F=48.908,P<0.05;女:F=59.801,P<0.05)。该地区健康人群血清Cys-C的参考区间男性:44岁以下为0.56~0.98 mg/L,45~59岁为0.59~1.08 mg/L,60~74岁为0.69~1.24 mg/L,75岁以上为0.72~1.28 mg/L;女性:44岁以下为0.52~0.98 mg/L,45~59岁为0.56~0.99 mg/L,60~74岁为0.59~1.12 mg/L,75岁以上为0.69~1.22 mg/L。结论健康人群血清Cys-C浓度存在着年龄和性别差异,应建立自己实验室健康人群血清Cys-C的参考范围。 Objective To established reference range of serum cystatin C(Cys-C)by the investigated data from healthy people in baoji.Methods Venous blood samples from healthy adults of male 720 cases and female 722 cases were collected,and then they were detected serum cystatin Cys-C by particle-enhanced nephelometric immunoassay method.Results The mean of serum Cys-C of healthy adults men was higher than women’s (t=11.625,P〈0.05).The levels of serum Cys-C of male and female increase with age (male:F=48.908,P〈0.05;female:F=59.801,P〈0.05).The serum Cys-C level’s reference intervals of healthy adults in Baoji were as following:male:0.56~0.98 mg/L (≤44 years),0.59~1.08 mg/L (45~59 years),0.69~1.24 mg/L (60~74 years),0.72~1.28 mg/L (≥75 years);female:0.52~0.98 mg/L (≤44 years),0.56~0.99 mg/L (45~59 years),0.59~1.12 mg/L (60~74 years),0.69~1.22 mg/L (≥75 years).Conclusion The level of serum Cys-C of healthy adults was a significant difference between age and gender.So every laboratory should establish their own reference range of serum Cys-C.
出处 《现代检验医学杂志》 CAS 2016年第6期141-142,146,共3页 Journal of Modern Laboratory Medicine
关键词 胱抑素C(Cys-C) 参考区间 健康人群 颗粒增强散射免疫比浊法 reference range healthy people particle-enhanced nephelometric immunoassay method
  • 相关文献

参考文献6

二级参考文献48

  • 1李玉艳,杨振坤,李强.胱抑素C在临床中的应用进展[J].国际检验医学杂志,2006,27(9):812-813. 被引量:106
  • 2赵翠生,王红洲,张翀,何莉.兰州市正常新生儿血液生化26项指标参考范围调查[J].国际检验医学杂志,2007,28(3):211-213. 被引量:5
  • 3徐静,王清涛,徐国宾.几种人血清肌酐常规测定方法与反相高压液相色谱测定法的比对研究[J].中华检验医学杂志,2007,30(6):683-686. 被引量:6
  • 4Wuyts B, Bernard D, Van-Den-Noortgate N,et al. The impact of metrological traceability on the validity of creatinine measurement as an index of renal function[J]. Accred Qual Assur,2004,10(1- 2) : 15-19. 被引量:1
  • 5Kabanda A,Jadoul M, Pochet JM, et al: Determinants of the serum concentrations of low meoleeular weight pro- teins in patients on maintenance hemodialySis[J]. Kidney Int,1994,45(6) : 1689-1696. 被引量:1
  • 6Cattaneo A, Sansor J L,Prevot D, et al. Turk V, Cystatin Proteinases and their inhibitors [M]. Berlin: Walter de Grugter, 1986:507-516. 被引量:1
  • 7Akhtar MH, Emara M, Moselhi HE, et al. comparing measures of cystatin C in human sera by there methods [J]. Am .l Nephol,2008,29(5):381-391. 被引量:1
  • 8Herget-Rosenthal S, Marggraf G, H using J, et al. Early detection of acute renal failture by serum cystatin C[J]. Kidney Jnt, 2004, 66:1115-1122. 被引量:1
  • 9Strevens H, Wide-swensson D, Torffvit O, et al. Serum cystation c for assessment of glomerular filtration rate in pregnant and non- pregnant women, indication of altered filtration process in preg- nancy[J]. Scand Clin Lab Invest, 2002,62 : 141-147. 被引量:1
  • 10Christensson AG, Grubb AO, Nilsson JA, et al. Serum cystatin C advantageous compared with serum creatinine in the detection of mild but not severe diabetic nephropathy[J]. Intern Med,2004, 256(6):510-518. 被引量:1

共引文献42

同被引文献24

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部