摘要 目的:探讨个性化植入非球面人工晶状体使全眼球差接近+0.1μm方法的可行性。方法:对行白内障超声乳化人工晶状体植入术的患者74例82眼随机分为试验组和对照组,术前均应用Pentacam测量角膜球差,试验组以术后全眼球差尽量接近+0.1μm为原则植入TecnisZ CB00、Hoya60AD、ADAPT-AO三种不同的非球面人工晶状体,对照组均植入ADAPT-AO非球面人工晶状体。术后3mo测量裸眼视力、最佳矫正视力、角膜球差和全眼球差。结果:术后3mo两组患者间裸眼视力、最佳矫正视力对比差异无统计学意义(t=0.817、0.343,P>0.05);术前和术后的角膜球差对比两组均无统计学意义(t=0.688、0.592,P>0.05);试验组和对照组术后3mo全眼球差对比有统计学意义(t=5.408,P<0.05);试验组不同人工晶状体组间全眼球差术前预测值和术后实际值比较均无统计学意义(t=1.943、2.033、0.032,P>0.05);全眼球差预测偏差值与术前角膜球差呈正相关(r=0.834,P<0.05)。结论:根据患者的角膜球差个性化地植入非球面人工晶状体可以达到有效降低全眼球差的目的,具有可行性。 AIM: To analysis the feasibility of selectively targeting +0.1μm total spherical aberration by personalized aspheric intraocular lens implantation. METHODS:Seventy-four cases(82 eyes)were randomly divided into experimental and control group, the corneal spherical aberration with 6mm pupil diameter was measured with Pentacam before surgery. Patients in experimental group received TecnisZCB00, Hoya60AD and ADAPT-AO, three different aspheric intraocular lenses, and the principle as the total spherical aberration close to +0.1μm. Patients in control group received ADAPT-AO aspheric intraocular lens. The uncorrected visual acuity, best corrected visual acuity, corneal spherical aberration and total spherical aberration were measured after 3mo.RESULTS:There was no statistically significant difference in the uncorrected visual acuity, best corrected visual acuity between the two groups(t=0.817, 0.343, P〉0.05). The comparison of corneal spherical aberration of the two groups showed no statistical significance before and after surgery(t=0.688, 0.592, P〉0.05). The difference of total ocular aberrations were statistically significant between two groups(t=5.408,P〈0.05). In the experimental group, there were no significant difference in total ocular aberrations among the different intraocular lens group between preoperative predictive value and postoperative value(t=1.943, 2.033, 0.032, P〉0.05). The prediction error of total ocular aberrations were positively correlated with the preoperative corneal spherical aberration(r=0.834, P〈0.05). CONCLUSION:The personalized aspheric intraocular lens implantation based on preoperative corneal spherical aberration is feasible. This method can reduce postoperative total ocular aberrations and make the aberrations close to the predictive value.
出处 《国际眼科杂志》 CAS 2017年第1期88-90,共3页 International Eye Science
关键词 非球面人工晶状体 球面像差 白内障 aspheric intraocular lens spherical aberration cataract
  • 相关文献

参考文献4

二级参考文献60

  • 1Vilarrodona L,Barrett GD,Johnson B.High order aberrations in pseudophakia with different intraoeular lenses.J Cataract Refract Surg,2004,30:571-575. 被引量:1
  • 2Jack TH,Patricia AP,Gabor K,et al.A new intraocular lens design to reduce spherical aberration of pserdophakic eyes.J Refract Surg,2002,18:683-691. 被引量:1
  • 3Dick HB.Recent developments in aspheric intraocular lenses.Curr Opin Ophthalmol,2009,20:25-32. 被引量:1
  • 4Artal P,Berrio E,Guirao A,et al.Contribution of the cornea and internal surfaces to the change of ocular aberrations with age.J Opt Soc Am A Opt Image Sci Vis,2002,19:137-143. 被引量:1
  • 5Kim SW,Ahn H,Kim EK,et al.Comparison of higher order aberrations in eyes with aspherical or spherical intraocular lenses.Eye,2008,22:1493-1498. 被引量:1
  • 6Awwad ST,Warmerdam D,Bowman RW,et al.Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses.J Refract Surg,2008,24:619-625. 被引量:1
  • 7Altmann GE,Nichamin LD,Lane SS,et al.Optical performance of 3 intraocular lens designs in the presence of decentration.J Cataract Refract Surg,2005,31:574-585. 被引量:1
  • 8Holladay JT,Piers PA,Koranyi G,et al.A new intraocular lens design to reduce spherical aberration of pseudophakic eyes.J Refract Surg,2002,18:683-691. 被引量:1
  • 9Beiko G,Haigis W,Steinmueller A.Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values.J Cataract Refract Surg,2007,33:848-858. 被引量:1
  • 10Packer M,Fine IH,Hoffman RS.Aspheric intraocular lens selection based on corneal wavefront.J Refract Surg,2009,25:12-20. 被引量:1

共引文献23

同被引文献37

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部