期刊文献+

单球中子能谱仪的发展概况 被引量:2

Overview of Single-sphere Neutron Energy Spectrometer
下载PDF
导出
摘要 本文调研了国内外多家实验室的多探头单球中子能谱仪技术现状,核心探测器主要是活化片、热释光剂量计、6Li-7Li对玻璃闪烁体、硅二极管、位置灵敏正比计数器等。针对这几种单球中子能谱仪的结构设计、能量响应模拟、能谱实验测量等进行了讨论分析。 Generally, several kinds of thermal neutron detectors such as activation foils, thermolu- miniscent dosimeters (TLD),6Li-7Li pairs glass scintillators, position-sensitive proportional counter, et al, were used as the coredeteetorsin the single-sphere neutron energy spectrometers. According to the de- velopment of multi-detector single-sphere neutron energy spectrometer, techniquesof structuredesign, ener- gy response simulation and neutron energy spectrum measurement were narrated andanalyzed in this paper.
出处 《宇航计测技术》 CSCD 2016年第5期47-53,共7页 Journal of Astronautic Metrology and Measurement
关键词 中子能谱 单球 活化片 热释光剂量计 6Li-7Li对玻璃闪烁体 位置灵敏正比计数器 Neutron energy spectrum Single sphere Activation foils TLD 6Li-7Li pairs glass scintillators Position-sensitive proportional counter
  • 相关文献

参考文献2

二级参考文献16

  • 1陈常茂 等.多球中子探测器能量响应特性的研究[J].辐射防护,1983,3(1):14-14. 被引量:1
  • 2Aroua A, et al. Evaluation and test of the response matrix of a multisphere neutron spectrometer in a wide energy range, part Ⅱ Simulation[J].Nucl Instrum Methods, 1992, A321(2) :333. 被引量:1
  • 3Nolan EH, et al.. The response of Bonner spheres ro neutrons from thermal energy to 17. 3MeV[J].Nucl Instrum Methods, 1985, A238(3) :509. 被引量:1
  • 4Aroua A et al. Improved neutron spectrometerbased on bonner spheres [J]. Radi Prot Dosi,1997, 70(1-4):285. 被引量:1
  • 5Liu JC,et al. Neutron spectral measurements at ORNL[J]. Radi Prot Dosi 1990, 30(3):169. 被引量:1
  • 6Karny M, et al. Bayes-based solution of dosimteric problem and related unfolding to bonner spectrometer[J]. Radioisotopy, 1989,30(5) :350. 被引量:1
  • 7MCNP4A. Monte Carlo N-particle transport code system. Los Alamos national laboratory, Los Alamos, New Xexico, 1993. 被引量:1
  • 8Wiegel B, et al. Calculations of the response functions of bonner spherical 3He proportional counter using a realistic detector model[J]. PTB-Bericht N-21, 1994. 被引量:1
  • 9Akira U,et al. Development of position helium-3 proportional counter for thermal neutrons with novel signal readout[J]. Journal of Nucl Sci Tech,1990, 27(8): 712. 被引量:1