期刊文献+

保乳术前肿瘤MRI体积与术后标本体积及基于金属夹勾画术腔体积比较研究 被引量:2

Gross tumor volume delineation in patients undergoing breast–conserving surgery:a comparative study of preoperative magnetic resonance imaging, postoperative specimen, and lumpectomy cavity based on surgical clips
原文传递
导出
摘要 目的 探讨保乳患者术前MRI肿瘤体积与术后标本测量体积及基于金属夹勾画的瘤床体积间的差异性与相关性.方法 2014—2015年间50例乳腺癌保乳患者入组.基于术前MRI勾画GTV并定义为GTVMRI,其边界外扩1.0 cm得到GTVMRI+1.测量切除标本体积并测量和计算病理体积,分别定义为GTVES和GTVPAT.在定位CT图像上基于术腔边界金属夹勾画GTV,并定义为GTVTB.Friedman检验,Wilcoxon法两两比较,Spearman等级相关分析.结果 GTVMRI、GTVMRI+1、GTVPAT、GTVES、GTVTB中位数(范围)分别为0.97(0.01-6.88)、12.58(3.90-34.13)、0.97(0.01-2.36)、15.46(1.15-70.69)、19.24(4.72-54.33)cm3.GTVMRI与GTVPAT、GTVMRI+1与GTVES、GTVTB与GTVES差异均无统计学意义(P=0.188、0.07、0.264).GTVTB、GTVES与GTVMRI均无相关性(P=0.378、0.071),GTVTB、GTVES与GTVMRI+1也均无相关性(P=0.375、0.068),而GTVTB与GTVES呈正相关(r=0.488,P=0.004).结论 在非影像引导情况下,保乳治疗的患者基于触诊范围行局部肿瘤切除术时,切除标本体积及基于金属夹勾画的术腔体积与基于术前MRI图像所勾画与构建的肿瘤体积均无相关性. Objective To explore the gross tumor volume ( GTV ) difference and correlation between preoperative magnetic resonance imaging ( MRI) , postoperative specimen, and lumpectomy cavity based on surgical clips. Methods Fifty patients with breast cancer undergoing breast-conserving surgery were enrolled as subjects from 2014 to 2015. GTVMRI was defined as tumor volume based on preoperative MRI scans, while GTVMRI+1 was defined as GTVMRI plus a 1. 0-cm margin. GTVES was defined as the volume of excised specimen, while GTVPAT was defined as the pathological volume of the specimen. GTVTB was defined as tumor volume based on lumpectomy cavity localized by surgical clips on computed tomography images. Comparison between any two GTVs was made by Friedman test and Wilcoxon test. A correlation analysis was made by Spearman rank correlation. Results The median values of GTVMRI , GTVMRI+1 , GTVPAT, GTVES, and GTVTB were 0. 97(0. 01-6. 88), 12. 58(3. 90-34. 13), 0. 97(0. 01-2. 36), 15. 46 (1. 15-70. 69), and 19. 24(4. 72-54. 33) cm3, respectively. There were no significant differences between GTVMRI and GTVPAT , between GTVMRI+1 and GTVES , and between GTVES and GTVTB ( P=0. 188, 0. 07, 0. 264). Neither GTVES nor GTVTB was correlated with GTVMRI(P=0. 071, 0. 378) or GTVMRI+1(P=0. 068, 0. 375). GTVTB was positively correlated with GTVES(r=0. 488, P=0. 004). Conclusions For patients undergoing breast-conserving therapy, during lumpectomy guided by palpation rather than imaging, neither the volume of excised specimen nor lumpectomy cavity based on surgical clips are correlated with tumor volume based on preoperative MRI.
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2016年第12期1314-1318,共5页 Chinese Journal of Radiation Oncology
基金 山东省医药卫生科技发展计划项目(2013WS0346)
关键词 磁共振成像 保乳术 切除标本 术腔体积 乳腺肿瘤 Magnetic resonance imaging Breast conservation therapy Excised specimen Lumpectomy cavity Primary tumor
  • 相关文献

参考文献1

二级参考文献21

  • 1Dzhugashvili M, Tournay E, Pichenot C, et al. 3D-conformal accelerated partial breast irradiation treatment planning:the value of surgical clips in the deIineation of the |umpectomy cavity. Radiat Onco1,2009 ,4 :70. 被引量:1
  • 2Dzhugashvili M, Piehenot C, Dunant A, et al. Surgical clips assist in the visualization of the lumpectomy cavity in three- dimensional eonformal accelerated partial-breast irradiation. Int J Radiat Oncol Biol Phys,2010,76 : 1320-1324. 被引量:1
  • 3Shaikh T, Chen T, Khan A, et al. Improvement in interobserver accuracy in delineation of the lumpectomy cavity using fiducial markers. Int J Radiat Oneol Biol Phys ,2010,78 : 1127-1134. 被引量:1
  • 4Giezen M, Kouwenhoven E, Seholten AN, et al. MRI-versus CT- based volume delineation of lumpectomy cavity in supine position in breast-conserving therapy: an exploratory study. Int J Radiat Oncol Biol Phys,2012,82 : 1332-1340. 被引量:1
  • 5Qi XS, White J, Rabinovitch R, et al. Respiratory organ motion and dosimetric impact on breast and nodal irradiation. Int J RadiatOncol Biol Phys,2010,78:6094517. 被引量:1
  • 6Liao ZW, Guan XX, Li FY, et al. Accelerated partial breast irradiation:use of four-dimensional CT for target localization and ssessment of intrafractlonal motion. Oncol Res,2010,18:503-507. 被引量:1
  • 7Wang W, Li BJ, Hu HG, et al. Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT. J Radiat Res,2013 ,In press. 被引量:1
  • 8Kimva YM, Castro-Pena P, Hijal T, et al. Improving the definition of tumor bed boost with the use of surgical clips and image registration in breast cancer patients. Int J Radiat Oncol Biol Phys,2010,78 : 1352-1355. 被引量:1
  • 9Thurean S, Oden S, Mokaouim R, et al. Assessing the contribution of a standardized method in defining the tumor bed using surgical clips in breast cancer. Cancer Radiother, 2012,16: 100-106. 被引量:1
  • 10Ehler ED, Tome WA. On correlated sources of uncertainty in four dimensional computed tomography data sets. Technol Cancer Res Treat ,2010,9:299-306. 被引量:1

共引文献9

同被引文献14

引证文献2

二级引证文献5

相关作者