期刊文献+

表面温度测量方式对喷雾冷却表面传热特性的影响 被引量:2

Influence of temperature measurement method on surface heat transfer during spray cooling
下载PDF
导出
摘要 喷雾冷却在工业过程中应用广泛,制冷剂喷雾是激光皮肤手术中实施表皮冷保护的必要手段。为提高冷却效率,需要通过表面温度的测量反推表面传热特性。为探索不同表面温度测量方式对实验结果的影响,搭建了瞬态喷雾冷却实验台,分别使用磁控溅射薄膜热电偶(TFTC)、丝状热电偶(FTC)和片状热电偶(STC)研究了R404A制冷剂喷雾环氧树脂表面传热特性的差异。实验结果表明,磁控溅射薄膜热电偶(TFTC)热响应性能最佳,能准确及时地反映表面温度的瞬态变化且可与热通量变化准确对应。丝状热电偶(FTC)和片状热电偶(STC)属于间接测温,温度变化存在明显滞后,影响热通量、对流传热系数等表面传热特性的精确分析。薄膜溅射热电偶测温是准确研究瞬态喷雾冷却表面传热过程的可靠手段,可为临床治疗提供理论指导。 Spray cooling is widely used in industries. Cryogen spray cooling has been implemented for the epidermis protection during laser surgery. For the improvement of cooling efficiency, the surface temperature was measured to calculate the surface heat transfer characteristics by the reverse heat conduction method. In order to investigate the influence of temperature measurement methods on the experimental result, a transient spray cooling rig was constructed to study the different heat transfer characteristics by using the thin film thermocouple(TFTC) fabricated by magnetron sputtering, the fine thermocouple(FTC) and the slice thermocouple(STC). The result suggested that the TFTC had the most sensitive thermal response, which can accurately reflect the temperature variation and corresponding heat flux. As for the FTC and STC, due to the limitation of indirect measurement, there was an obvious lag in temperature variation, which affected the subsequent analysis such as heat flux and apparent convective heat transfer coefficient. The employment of thin film thermocouple ensured the precise investigation of surface heat transfer during transient spray cooling, with reliable reference for clinical treatment.
出处 《化工学报》 EI CAS CSCD 北大核心 2016年第11期4558-4565,共8页 CIESC Journal
基金 国家自然科学基金重点项目(51336006) 中央高校基本科研业务费专项资金~~
关键词 喷雾冷却 表面传热 温度测量 R404A spray cooling surface heat transfer temperature measurement R404A
  • 相关文献

参考文献3

二级参考文献27

  • 1叶方伟.薄膜热电偶的发展及其应用[J].材料导报,1995,9(5):28-32. 被引量:9
  • 2贾颖,孙宝元,曾其勇,徐静.磁控溅射法制备NiCr/NiSi薄膜热电偶温度传感器[J].仪表技术与传感器,2006(2):1-3. 被引量:13
  • 3Nelson J S, Milner T E, Anvari B, et al. Dynamic epidermal cooling during pulsed laser treatment of port wine stain, a new methodology with preliminary clinical evaluation [J]. Arch. Dermatol. , 1995, 131 (6): 695-700. 被引量:1
  • 4Bunsho Kao, Kelly Kristen M, Aguilar Guillermo, etal. Evaluation of cryogen spray cooling exposure on in vitro model human skin [J]. Laser in Surgery and Medicine,2004, 34 (2): 146-154. 被引量:1
  • 5Anvari B, Tanenbaum B S, Milner T E, Tang K, et al. Spatially selective photocoagulation o{ biological tissues {easibility study utilizing cryogen spray cooling [J]. Appl. Opt. , 1996, 35 (19): 3314-3320. 被引量:1
  • 6Aguilar G, Verkruysse W, Majaron B, et al. Measurement of heat flux and heat transfer coefficient during continuous cryogen spray cooling for laser dermatologic surgery [J]. IEEE Journal of Selected Topics in Quantum Electronics, 2001, 7 (6): 1013 -1021. 被引量:1
  • 7Svaasand L O, Randeberg L L, Aguilar G, et al. Cooling efficiency of cryogen spray during laser therapy of skin [J]. Lasers in Surgery and Medicine, 2003, 32 (2) : 137-142. 被引量:1
  • 8Aguilar G, Wang Guo-Xiang, Nelson J Stuart. Dynamic behavior of cryogen spray cooling: effects of spurt duration and spray distance [J]. Lasers in Surgery and Medicine, 2003, 32 (2): 152-159. 被引量:1
  • 9Aguilar Guillermo, Wang Guo-Xiang, Nelson J Stuart. Effect of spurt duration on the heat transfer dynamics during cryogen spray cooling[J]. Phys. Med. Biol. , 2003, 48 (14): 2169-2181. 被引量:1
  • 10Jia W, Aguilar G, Wang G X, Nelson J S. Heat-transfer dynamics during cryogen spray cooling of substrate at different initial temperatures [J]. Physics in Medicine and Biology, 2004, 49 (23): 5295 5308. 被引量:1

共引文献18

同被引文献22

引证文献2

二级引证文献7