摘要
介绍了高低压无功补偿装置改造的必要性以及改造方案的制定,应用TSC无功补偿的先进技术,通过对10 k V母线段和380 V低压母线段全部无功补偿装置的改造,从而达到了提高电压质量、功率因数和降低线损的目的。
Are introduced in this paper our company high and low voltage reactive compensation equipment of the transformation of the necessity and transformation plan formulation, the TSC application without the advanced technology of reactive power compensation, through to 10 kV bus segments and 380 V low voltage bus line no modification of reactive power compensation device, so as to improve the voltage quality and power factor and reduce the loss of purpose.
出处
《中国氯碱》
CAS
2016年第9期41-43,共3页
China Chlor-Alkali
关键词
TSC无功补偿装置特点
过零投切
改造方案
无功补偿改造效果
TSC reactive power compensation device characteristics
zero crossing
reconstruction scheme
reactive power compensation reconstruction effect