期刊文献+

徐大堡核电厂丧失给水严重事故序列消氢分析

Hydrogen Removal Analysis in Severe Accident Induced by Loss of Feed Water for XUDAPU Nuclear Power Plant
下载PDF
导出
摘要 丧失给水事故发生后,若相关安全保护系统失效,将导致一回路丧失热阱,从而使堆芯发生裸露,进一步发生锆水反应产生氢气,氢气进入安全壳有可能发生燃烧或爆炸,产生的高温高压将威胁安全壳的完整性。文章通过M AAP4程序计算分析了丧失给水引发的严重事故后氢气控制系统的消氢能力。 After loss of feed water accident, if the safety features fail to start up, the primary will loss heat sink, which may lead core uncover to generate hydrogen by Zirconium-Water Reaction. The hydrogen release to the containment could cause deflagration or detonation ,which would produce both high thermal and pressure loads on the containment. This paper use MAAP4 to analyze the hydrogen removal capability after the severe accident induced by loss of feed water.
作者 刘杨 石雪垚
出处 《南方能源建设》 2016年第3期36-39,共4页 Southern Energy Construction
关键词 丧失给水 严重事故 消氢 MAAP4 loss of feed water severe accident hydrogen removal MAAP4
  • 相关文献

参考文献3

  • 1濮继龙著..压水堆核电厂安全与事故对策[M].北京:原子能出版社,1995:338.
  • 2杜福伟.AP1000核电厂氢气控制措施[J].科技视界,2014(12):259-260. 被引量:6
  • 3Fauske Associates LLC. MAAP4 modular accident analysis programfor LWR power plants user’s manual [M]. ProjectRP3131-02 ( prepared for EPRI) , 1994. 被引量:1