期刊文献+

Site amplification effects as an explanation for the intensity anomaly in the Hanyuan Town during the Wenchuan Mw 7.9 earthquake 被引量:5

Site amplification effects as an explanation for the intensity anomaly in the Hanyuan Town during the Wenchuan M_w 7.9 earthquake
下载PDF
导出
摘要 The Hanyuan Town is located approximately 200 km from the macro-epicenter of the great Wenchuan earthquake. However, it is within the only Intensity VIII zone, surrounded by a region of Intensity VI. The objective of this study was to investigate this high-intensity anomaly with respect to the site amplifications in the Hanyuan Town. The base inputs were derived from the records at a nearby strong-motion station because no records were available from the town. The characteristics of the subsurface formations and their dynamic properties at a typical site in the town were obtained by drilling, field tests and laboratory tests. Seismic response and parametric sensitivity analyses of the site were conducted using Shake 91, and the results were compared with the provisions for rare earthquakes from the Chinese Code for Seismic Design of Buildings (GBJ11-89). The results showed that the average peak acceleration at the site during the Wenchuan earthquake is similar to the code-specified value under rare earthquakes, that the corresponding spectral accelerations for periods betwcen approximately 0.35 and 0.75 s are significantly stronger than those specified by the code and that the average amplification factor at the site is significantly higher than the mean value of the site class. These findings indicate that the high-intensity anomaly in the town was primarily caused by site amplification effects from the unique structure of the soil strata. The Hanyuan Town is located approximately 200 km from the macro-epicenter of the great Wenchuan earthquake. However, it is within the only Intensity VIII zone, surrounded by a region of Intensity VI. The objective of this study was to investigate this high-intensity anomaly with respect to the site amplifications in the Hanyuan Town. The base inputs were derived from the records at a nearby strong-motion station because no records were available from the town. The characteristics of the subsurface formations and their dynamic properties at a typical site in the town were obtained by drilling, field tests and laboratory tests. Seismic response and parametric sensitivity analyses of the site were conducted using Shake 91, and the results were compared with the provisions for rare earthquakes from the Chinese Code for Seismic Design of Buildings (GBJ11-89). The results showed that the average peak acceleration at the site during the Wenchuan earthquake is similar to the code-specified value under rare earthquakes, that the corresponding spectral accelerations for periods betwcen approximately 0.35 and 0.75 s are significantly stronger than those specified by the code and that the average amplification factor at the site is significantly higher than the mean value of the site class. These findings indicate that the high-intensity anomaly in the town was primarily caused by site amplification effects from the unique structure of the soil strata.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第3期435-444,共10页 地震工程与工程振动(英文刊)
基金 National Natural Science Foundation of China under Grant Nos.50978237 and 41172293
关键词 Wenchuan earthquake Hanyuan Town high-intensity anomaly site amplification rare earthquake Wenchuan earthquake Hanyuan Town high-intensity anomaly site amplification rare earthquake
  • 相关文献

参考文献12

二级参考文献114

共引文献330

同被引文献25

引证文献5

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部