摘要
晶闸管投切电容器(TSC)无功补偿装置是静止无功补偿技术的发展方向,从TSC无功补偿装置的组成结构、主接线形式、晶闸管过零触发方式、内部检测与控制电路原理等方面介绍了TSC无功补偿装置。随着TSC技术的发展,TSC无功补偿装置将取代接触器投切式无功补偿装置,在高低压配电系统中应用更广泛。
Thyristor switchable capacitor (TSC) reactive power compensation device is the development direction of static reactive power compensation technology. An introduction was presented on TSC reactive power compensation device in the aspects of its composition structure, the main connection form, thyristor zero-cross trigger mode, principles of internal detection and control circuit. In company with the development of TSC technology, TSC reactive power compensation device will replace the original reactive power compensation device switched by the contactor and has wide application in high and low voltage distribution system.
出处
《上海电气技术》
2016年第3期69-72,共4页
Journal of Shanghai Electric Technology