期刊文献+

1.8mm和3.0mm透明角膜切口白内障超声乳化术后泪膜和眼表变化对比研究 被引量:8

A comparative study on the changes of tear film and ocular surface after 1.8 mm and 3.0 mm clear corneal incision for ultrasonic phacoemulsification of cataract
下载PDF
导出
摘要 目的对比观察临床应用1.8 mm和3.0 mm透明角膜切口白内障超声乳化术后泪膜和眼表变化情况。方法选取2013年9月至2015年2月进行诊治的94例白内障患者,按随机数字表法随机分为A、B两组各47例,A组患者给予1.8 mm透明角膜切口白内障超声乳化术,B组患者行3.0 mm透明角膜切口白内障超声乳化术,对比分析两组患者术后2 d、5 d、10 d、30 d时的泪膜和眼表变化情况。结果两组患者术前主观干燥异物感(DES)、Schirmer试验(SIt)、泪膜破裂时间(BUT)以及角膜荧光素染色积分(CFS)组间比较无显著差异(P>0.05),术后2 d、5 d、10 d时两组患者的DES及SIt均较治疗前明显升高(P<0.05),组间比较A组明显低于B组(P<0.05),术后30 d时A组患者的DES及SIt恢复到术前水平,B组患者仍明显高于术前(P<0.05);术后2 d、5 d、10 d时两组患者的BUT及CFS均较治疗前明显降低(P<0.05),术后30 d时A组患者的BUT及CFS恢复到术前水平,B组患者仍较术前差异明显(P<0.05)。结论相比3.0 mm透明角膜切口,1.8 mm透明角膜切口白内障超声乳化术对患者泪膜及眼表损伤较小,值得推广应用。 Objective To observe the changes of tear film and ocular surface after 1. 8 mm and 3. 0 mm clear corneal incisions for ultrasonic phacoemulsification of cataract. Methods A total of 94 patients with cataract treated in this hospital during September 2013 to February 2015 were selected for this study, and they were randomly divided into two groups, group A and group B, each group with 47 cases. Patients in group A were treated with 1. 8 mm clear comeal incision for ultrasonic phacoemulsification of cataract, and patients in group B were treated with 3.0 mm clear corneal incision for ultrasonic phacoemulsification of cataract. The changes in tear film and ocular surface of patients in these 2 groups were analysed in 2 d, 5 d, 10 d and 30 d after operation. Results The difference in preoperative subjective dry foreign body feeling ( DES) , Schirmer test (Sit), tear film break - up time (BUT) and comeal fluorescein staining points (CFS) between patients of these 2 groups was not significant ( P 〉 0. 05), DES and Sit in patients of these 2 groups in 2 d, 5 d and lOd after the operation were significantly decreased ( P 〈 0. 05) , they in group A were lower than those of group B ( P 〈 0. 05) , while levels of DES and Sit in patients of group A were recovered in 30 d after the operation, they in patients of group B were significantly higher than those before operation ( P 〈 0 . 0 5 ) . BUT and CFS in patients of these 2 groups in 2 d, 5 d and 10 d after the operation were significantly decreased than those before treatment ( P 〈0. 05). While BUT and CFS in patients of group A in 30 d after the operation were recovered to preoperative level, patients in group B still had clear difference when they compared with those before operation ( P 〈 0. 05). Conclusion In comparison with the 3. 0 mm clear corneal incision ,1.8 mm clear corneal incision for ultrasonic phacoemulsification of cataract has less impairment in tear film and ocular surface of patient
作者 吴杰
出处 《临床和实验医学杂志》 2016年第18期1790-1793,共4页 Journal of Clinical and Experimental Medicine
基金 陕西省科技厅资助基金项目(编号:20132350)
关键词 白内障超声乳化术 透明角膜切口 泪膜 眼表 Cataract ultrasonic phacoemulsification Clear corneal incision Tear film Ocular surface
  • 相关文献

参考文献8

二级参考文献68

共引文献46

同被引文献86

二级引证文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部