4Calandruccio RA.The history of the Campbell Clinic[J].Clin Orthop Relat Res,2000(374):157-170. 被引量:1
5Laskin RS.Flexion space configuration in total knee arthroplasty[J].J Arthroplasty,1995,5(5):657-660. 被引量:1
6Ozcelik A,Seber S,Omeroˇglu H.Bone anatomy and rotational alignment in total knee arthroplasty[J].Clin Orthop Relat Res,2004(422):270. 被引量:1
7Akagi M,Yanmshita E,Nakagawa T,et al.Relationship between frontal knee alignment and reference axes in the distal femur[J].Clin Orthop Relat Res,2001(388):147-156. 被引量:1
8Victor J,Van Doninck D,Labey L,et al.A common reference frame for describing rotation of the distal femur:a ct-based kinematic study using cadavers[J].J Bone Joint Surg Br,2009,91(5):683-690. 被引量:1
9Asano T,Akagi M,Nakamura T.The function flexion-extension axis of the knee corresponds to the surgical epieondylar axis:in vivo analysis using a biplanar imagematching technique[J].J Arthroplasty,2005,20(8):1060-1067. 被引量:1
10Yau WP,Chiu KY,Tang WM.How precise is the determination of rotational alignment of the femoral prosthesis in total knee arthroplasty:an in vivo study[J].J Arthroplasty,2007,22(7):1042-1048. 被引量:1
二级参考文献52
1Talbot S, Bartlett J. The anterior surface of the femur as a new landmark for femoral component rotation in total knee arthroplasty[J]. Knee Surg Sports Traumatol Arthrosc,2008, 16(3):258-262. 被引量:1
2Hollister AM, Jatana S, Singh AK, et al. The axes of rotation of the knee[J].Clin Orthop Relat Res,1993,(290):259-268. 被引量:1
3Olcott CW, Scott RD. A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty[J].J Arthroplasty,2000,15(1):22-26. 被引量:1
4Churchill DL,Incavo SJ,Johnson CC,et al.The transepicondylar axis approximates the optimal flexion axis of the knee[J]. Clin Orthop Relat Res, 1998,(356):111-118. 被引量:1
5Miller MC, Berger RA, Petrella AJ, et al.Optimizing femoral component rotation in total knee arthroplasty[J]. Clin Orthop Relat Res, 2001,(392):38-45. 被引量:1
6Akagi M, Yamashita E, Nakagawa T, et al. Relationship between frontal knee alignment and reference axes in the distal femur[J]. Clin Orthop Relat Res, 2001,(388): 147-156. 被引量:1
7Yoshino N, Takai S, Ohtsuki Y, et al. Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees[J]. J Arthroplasty,2001,16(4) :493-497. 被引量:1
8Griffin FM, Math K, Scuderi GR, et al. Anatomy of the epicondyles of the distal femur: MRI analysis of normal knees[J]. J Arthroplasty, 2000, 15(3): 354-359. 被引量:1
9Jerosch J, Peuker E, Philipps B, et al. Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis[J]. Knee Surg Sports Traumatol Arthrosc, 2002, 10(3):194-197. 被引量:1
10Jenny JY, Boeri C. Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement[J]. Acta Orthop Scand,2004,75(1):74-77. 被引量:1