KZ34震源是自主研发的国产可控震源,它是目前国内投入施工中吨位最大的可控震源。在2013年7月的吐哈项目中,个别震源在施工中出现了一些故障,主要状况是1号震源的振动性能曲线失真。本文从1号震源出现异常的振动性能曲线入手,结合震源在施工中的工况,对震源出现的故障进行了描述,对振动性能曲线和出现的故障进行了深入分析,最后对故障的解决进行了介绍。
KZ34 is the domestic vibrator of independent research and development, and also is currently the largest tonnage vibrator invested in the construction. In July 2013,some vibrators have been a variety of faults, leading to vibration performance curve distortion in the Tuha project. Starting from vibration performance curve, combining the performance disorder of KZ34 in working, the paper do a brief introduction to the problems and its analysis and solving process of the No. 1 vibrator in the Tuha project.
出处
《物探装备》
2016年第3期178-181,共4页
Equipment for Geophysical Prospecting