利用SLR检核GOCE卫星精密轨道 被引量:4

Evaluation of GOCE Precise Orbit Using SLR
下载PDF
导出
摘要 采用2009-11-01~2010-01-31三个月的SLR观测数据,对GOCE卫星运动学轨道PKI(precise kinematic orbit)进行检核。基于残差分析发现,SLR观测存在测站时距系统性偏差。消除测站时距偏差后,GOCE卫星PKI精密轨道的外符合精度达到1.5cm。 In this paper we present the method of satellite orbit validation with SLR measurements,and use SLR data observed from 1November 2009 until 31 January 2010(3 months)to validate the GOCE PKI(precise kinematic)orbit.Based on residual analysis,we find that system error due to station time bias and range bias exits and has not been removed in the SLR observation.After modeling and fitting the station time bias and range bias,we achieve the GOCE PKI orbit precision at the level of 1.5 cm.
出处 《大地测量与地球动力学》 CSCD 北大核心 2016年第8期719-722,共4页 Journal of Geodesy and Geodynamics
基金 国家973计划(2013CB733301) 国家自然科学基金(41004007 41274033) 测绘地理信息公益性行业科研专项(201512001) 中央高校基本科研业务费(2015214020202)~~
关键词 精密轨道 卫星激光测距 外部检核 时距偏差 precise orbit SLR validation station time bias and range bias
  • 相关文献

参考文献4

二级参考文献17

共引文献34

同被引文献37

引证文献4

二级引证文献10