摘要 以瞬时双kVp切换为核心的能谱CT成像技术是CT发展史上的重大变革。其不仅能提供CT值,还能提供单能量成像、能谱曲线、物质密度图、有效原子序数等参数信息,目前已逐渐应用于全身各个系统。能谱CT将影像诊断从形态学范畴带入了功能学范畴,不仅可以高清晰、低剂量成像,还能提供物质定量分析指标及工具,对于肺部疾病的诊断表现出特有的优势,如微细结构的显示、微小病灶的检出、疾病的精准诊断等。
出处 《中华放射学杂志》 CAS CSCD 北大核心 2016年第8期639-640,共2页 Chinese Journal of Radiology
  • 相关文献

参考文献13

  • 1McCollough CH, Leng S, Yu L, et al. Dual- and multi-energy CT: principles, technical approaches, and clinical applications [J]. Radiology, 2015, 276(3): 637-653. DOI:10.1148/radi- ol.2015142631. 被引量:1
  • 2Wu HW, Cheng J J, Li JY, et al. Puhnonary embolism detec- tion and characterization through quantitative iodine-based material decomposition images with spectral computed tomog- raphy imaging[J]. Invest Radiol, 2012, 47(1): 85-91. DOI: 10.1097/RLI.0b013 e31823441 a 1. 被引量:1
  • 3Krissak R, Henzler T, Reichert M, et al. Enhanced visualiza- tion of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography[J]. Invest Radiol, 2010, 45(6): 341-346. DOI: 10. i 097/RLI.0b013 e3181 dfda37. 被引量:1
  • 4Pessis E, Campagna R, Sverzut JM, et al. Virtual monochro- matic spectral imaging with fast kilovoltage switching: reduc- tion of metal artifacts at CT[J]. Radiographics, 2013, 33(2): 573-583. DOI:10.1148/rg.332125124. 被引量:1
  • 5Matsuda I, Akahane M, Sato J, et al. Precision of the measure- ment of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms[J]. Jpn J Radiol, 2012, 30(1): 34-39. DOI:10.1007/ s11604-011-0004-0. 被引量:1
  • 6茅国群,杨光钊,魏福全,程有根.新双源CT虚拟平扫技术在评估孤立性肺结节中的临床价值[J].中华放射学杂志,2013,47(8):717-721. 被引量:20
  • 7Gyobu T, Honda O, Kawata Y, et al. The effect of the virtual monochromatic spectral imaging for the metallic artifact and the pulmonary nodule detection[J]. J Comput Assist Tomogr, 2013, 37(5): 707-711. DOI:I 0.1097/RCT.0b013e31829e0164. 被引量:1
  • 8Hou WS, Wu HW, Yin Y, et al. Differentiation of lung cancers from inflammatory masses with dual-energy spectral CT imag- ing[J]. Acad Radiol, 2015, 22(3): 337-344. DOI:10.1016/j. acra.2014.10.004. 被引量:1
  • 9Aoki M, Takai Y, Narita Y, et al. Correlation between tumor size and blood volume in lung tumors: a prospective study on dual-energy gemstone spectral CT imaging[J]. J Radiat Res, 2014. 55(5/: 917-923. DOI:10.1093/irr/rru026. 被引量:1
  • 10刘金刚,刘亚,李丽新,赵兴圣,周茂义,邵伟光,岳奎涛,张东雯,李文强,粘琦玉,张帅,曹会志.CT能谱成像在诊断肿瘤淋巴结转移和肿瘤性质中的作用[J].中华放射学杂志,2011,45(8):731-735. 被引量:104

二级参考文献42

共引文献156

同被引文献22

引证文献4

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部