摘要
对长平洗煤厂二期系统分选工艺流程进行了详细介绍,又对现场出现的末原煤产品出现水分超标的原因进行了全面分析,同时提出了相应的整改措施,避免再次出现水分超标的煤质事故。
The paper introduced separation process in the second system of Changping Coal Washery in detail, comprehensively analyzed the reasons of excessive product moisture of slack coal on the scene, and puts forward the corresponding corrective measures to avoid excessive water quality accidents occurring again.
出处
《能源与节能》
2016年第8期76-77,104,共3页
Energy and Energy Conservation
关键词
末原煤产品水分
超标
原因
整改措施
product moisture of slack coal
excessive
reason
rectification measures